2-16. Auto Registration Diagnostics - Sony KP-57WV600 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SENSOR POSITIONS
FRONT OF SCREEN
1
0: UPPER SENSOR
1: LEFT SENSOR
2: RIGHT SENSOR
3: LOWER SENSOR

2-16. AUTO REGISTRATION DIAGNOSTICS

The TEST service item (PJE #72) can be used to determine if a sensor or sensor ampliÞ er is working properly. It can also be used to check
pattern positions.
133
Color:
CS/ZL:
Display/Loop:
DISPLAY/
LOOP
CS/ZL
(0)
0
(0)
X
(0)
3
1
X
• ERROR CODE SCREEN DISPLAY
Error codes in normal (customer) mode are not
displayed. You must enter PJE service mode to
0
2
3
0=Green, 1=Red, 2=Blue, 3=All
0=None, 1=Cent/Skew, 2=siZe/Lin, 3=Both
0=Display, 1:Loop
COLOR
ACTION
0
Normal calibration (no diagnostics).
X
Performs one adjustment cycle, then
displays average peak voltages for the
specified CS/ZL and Color.
3
Does nothing (can't display more than one
CS/ZL or Color at a time.)
X
Adjusts specified CS/ZL and Color
until a key is pressed. Useful for
measuring signals with oscilloscope.
S0
S0: 2.04 S1: 1.86
S2: 1.98 S3: 2.23
S1
S3
Sensor 0 peak voltage = 2.04 V, etc.
see the error code.
PJE
61
213
60
ERR
Color:
0 = Green
1 = Red
2 = Blue
Error Code:
(See Error List)
(Blue Sensor 3 Low Output)
S2
— 55 —
KP-57WV600/57WV700/
65WV600/65WV700
In service mode, the error will be displayed
in text format.
0
ERROR B
LO LEVEL S3
1
3
2

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Kp-57wv700Kp-65wv600Kp-65wv700