Parameter Table - Cordivari Bollyterm Home Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10.3.1

Parameter table

Parameter
Description
no.
0
Set point temp. Heat Pump
Heat Pump activation temperature
1
hysteresis
Heating
element
2
temperature setpoint
Heating element switch-on delay
3
time
Weekly
antibacterial
4
temperature
5
Antibacterial cycle time
6
Defrosting time
Heat exchanger temperature for
7
Defrosting start
Heat exchanger temperature for
8
Defrosting end
9
Max defrosting cycle time
10
Electronic expansion valve mode
11
Overheating ΔT
Electronic expansion valve steps
12
in manual mode
13
Antibacterial cycle start time
Tank "IN" temperature (lower T2
A
probe)
Tank "OUT" temperature (upper
B
T3 probe)
Evaporator temperature
C
(T4 probe)
D
Gas return temperature (T5 probe)
E
Ambient temperature (T1 probe)
F
Electronic expansion valve steps
H
Antibacterial cycle recording
Cod. 1910000001165 - nv01
PARAMETER TABLE
Range
10 ~ 70°C
2 ~ 15°C
switch-off
10 ~ 85°C
0 ~ 90min
cycle
50 ~ 70°C
0 ~ 90 min
30~90 min
-30 ~ 0°C
2 ~ 30°C
1 ~ 12 min
0/1
-9 ~ 9°C
10 ~ 47 steps
0~23
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
10 ~ 47 steps
1~99
- 43 -
Default
50°C
5°C
55°C
6min
70°C
30 min
45 min
-7°C
13°C
8 min
1
5°C
35 steps
23
Current detected value.
In case of malfunction, PP1 Error Code is displayed
Current detected value.
In case of malfunction, PP2 Error Code is displayed
Current detected value.
In case of malfunction, PP3 Error Code is displayed
Current detected value.
In case of malfunction, PP4 Error Code is displayed
Current detected value.
In case of malfunction, PP5 Error Code is displayed
Current value of electronic expansion valve opening degree No.*10
The number increases by a unit every time an antibacterial cycle is
completed (it resets after 99).
English
Notes
Editable
Editable
Editable
(Never exceed 75 °C)
t * 5 min
Editable
Editable
Editable
Editable
Editable
Editable
(0→manual, 1→auto)
Keep it
always on auto
Always use the default value
Always use the default value
Editable (time of day)
steps

Publicité