Photocell
External photocell h=50cm;
A
triggered on closure
External photocell h=100 cm;
B
triggered on closure
Internal photocell h=50 cm;
C
triggered on closure
Internal photocell h=100 cm;
D
triggered on closure

10.4 - MEMORIZING ALL RADIO TRANSMITTERS

The control unit contains a radio receiver for GTX4 transmitters; the trans-
mitter included in the box is already memorised and ready to use.
There are two ways of memorising a new transmitter:
• M ode 1: in this "mode" the radio transmitter is used as a whole, i.e. all
the keys carry out a preset command (the transmitter supplied with the
SL1S-SL10S is memorised using Mode 1). Obviously a radio transmitter
in mode 1 can only control one single automation; that is:
Key T1
"OPEN" command
Key T2
"Pedestrian opening" command
Key T3
"Only open" command
Key T4
"Only close" command
• M ode 2: each key can be associated to one of the four commands
available. If this mode is used appropriately 2 or more different automa-
tions can be controlled, for example:
Key T1
"Only open" command Automation N° 1
Key T2
"Only close" command Automation N° 1
Key T3
"OPEN" command Automation N° 2
Key T4
"OPEN" command Automation N° 3
Obviously each transmitter is treated separately and for one single control
unit there can be some transmitters memorised in mode 1 and others in
mode 2.
The overall maximum memory capacity is of 150 units; mode 1 memori-
sation occupies one unit per transmitter while mode 2 occupies one unit
per key.
Caution! – As memorisation procedures have a time limit (10 s), it
is im p ortant to read the instructions in the next paragraphs before
starting.
10.4.1 - Memorisation mode 1
01. Press key P1 [B] (fig. 43) for at least 3 s. When the LED P1 [A] (fig.
43) switches on release the key.
02. Within 10 s press any one key on the transmitter for at least 3 s to
memorise it. If the memorisation procedure is successful, the LED P1
will emit 3 flashes.
03. If there are other transmitters to be memorised repeat step 2 within the
next 10 s otherwise the memorisation phase will end automatically.
10.4.2 - Memorisation mode 2
With Mode 2 memorisation each key can be associated with any one of
the four commands: "OPEN", "Partially open", "Only open" and "Only
close".
TABLE 9
Jumpers
External photocell triggered
E
on opening
Internal photocell triggered on
F
opening
Single photocell that covers
the entire automation and
G
is triggered on closure and
opening
Note: normally there are no restrictions to the position of the two
elements that make up the photocell (TX-RX).
Only if photocell G is used with photocell B it is necessary to follow
the positions shown in fig. 41.
In Mode 2 each key requires its own memorisation phase.
01. If the transmitter to be memorised is already memorised (such as
the transmitters supplied which are already memorised in mode I)
the transmitter must be deleted following the procedure described in:
"10.4.4 - Deleting a radio transmitter".
02. Press key P1 [B] (fig. 43) on the control unit the number of times
equal to the required command, according to Table B (e.g. 3 times
for the "Only open" command").
03. Check that LED P1 [A] (fig. 43) flashes quickly for a number of times
equal to the command selected.
04. Within 10 s press the required key on the radio transmitter for at least
2 s to memorise it. If the memorisation procedure is successful, the
LED P1 will emit 3 slow flashes.
05. If there are other transmitters to be memorised for the same type of
command, repeat step 03 within the next 10 s otherwise the memo-
risation phase will end automatically.
43
once
twice
three times
Four times
Five times
Six times
Seven times
Eight times
Nine times
Ten times
Eleven times
Twelve times
Thirteen times
Photocell
TABLE B
"Open" command
"Pedestrian opening" command
"Only open" command
"Only close" command
"Stop" command
"Apartment block" open command
"High priority open" command
"Pedestrian opening 2" command
"Pedestrian opening 3" command
"Open+ block automation" command
"Close + block automation" command
"Block automation" command
"Unblock automation" command