N
G
For the connections and the technical data of the fixtures follow the
L
I
S
EXTRA FUNCTIONS WITH
H
!! FEED THE EXP CARD IN WHEN POWER IS NOT SUPPLIED !!
LÉGENDE
ATTENTION: Before connecting the connector 11, intended for safety edge during
opening, make sure that the version of the software of the command card is:
- v.02 or later versions => for command card KS (BC07050 e BC07052);
software version
In case the version of the software is earlier than the one indicated do not use the
connector 11, LEAVE IT FREE.
CAPTION
TR
=> Adjustment trimmer for the courtesy light time
1-2 => 24Vac power supply for photocells, FOTOOSTA units etc....
3-4 => Traffic light 1 contact
5-6 => Traffic light 2 contact
7-8 => Courtesy light contact
9
=> Photocell 2 contact (NC)
10
=> Pedestrian opening command (NO)
11
=> Contact for safety edge (NC) (ATTENTION - see previous note)
12
=> Common unit
EXPANDER
D2
photocell 2 contact signal
D3
Signal for pedestrian opening contact
D4
Signal for safety edge
D5
voltage available
N.B.: LED D2, LED D4 and LED D5 must always be turned on for a correct
functioning .
PEDESTRIAN OPENING BUTTON (10-12)
This command operates the partial opening of the gate and Its closing. When the gate Is
partly open, it is not possible to operate its total opening using the pedestrian command.
It is first necessary to close the gate than to open it totally.
NB: From modification SW.07 on cards KS and KS Super, operation of the gate is
as follows: during the opening stroke, the pause or the pedestrian closure, it is
possible to start the opening from any control connected to the card KS or KS
Super.
Through DIP 5 it is possible to choose the mode of function of the pedestrian command.
If DIP5 is set on OFF position => It is a cyclic command. Every command operates a
If DIP5 is set on ON position => Commands the opening when gate is closed. If another
LEARNING PROCEDURE FOR THE PEDESTRIAN OPENING
When the gate is closet and the closing limit switch is engaged
1 - First position the DIP2 on mode ON (the LED DL5 blinks quickly) and then DIP1
on mode ON (The LED DL5 blinks slowly).

OPTIONALS

relevant handbooks.
EXPANDER
(Code ACG5470)
CARD LED SIGNALS
change; e.g. open-stop-close-stop-open etc.
command is sent during the opening of the gate it will
have no effects. Commands the closing when the gate id
opened. If another command is sent during the closing
of the gate it will re-open the gate.
2 - Press the pedestrian button (10-12) => The sliding gate opens.
3 - Press the pedestrian button to stop the travel (thereby determining the gate opening).
4 - Wait the time you want the gate to remain open (excluded by DIP3 on OFF), then
press the pedestrian button to start the closing.
5 - Position DIP1 and 2 on mode OFF after the closing limit switch has been reached.
Safety devices are active during the programming and their intervention stops it (the LED
blinks no more but remains constantly turned on).
To repeat the programming, position DIP1 and 2 on mode OFF, close the gate and
repeat the procedure described above.
Pause times before the automatic pedestrian closing of the gate are set during the
programming procedure.
The max. pause time is 5 minutes.
You can start or stop the pause time using DIP3 (ON starts).
If the safety edge intervenes during the opening of the gate, it commands the reversal of
the movement. This reversal will continue even if the safety edge remains pressed.
During closing the safety edge is not active.
NB: from modification SW.07 on cards KS and KS Super,operation of fence is as
follows:
- during opening stroke, if resistance is encountered, motion is reversed to close;
- during closure stroke, if resistance is encountered; motion is reversed to
opening
- in case resistance load persists, a further inversion is initiated after 2 seconds,
followed by a third short inversion and thus signalling an alarm for fence failure
or jamming (contact NO).
- in case the fence remains blocked (contact NO), no further motion is allowed.
If it detects an object during the opening cycle, it then operates the closing of the gate at
the end of the interposition. If it detects one during the closing cycle, it then operates the
opening at the end of the interposition.
This function is particularly helpful when you want the gate to close immediately after you
passed it. If it is not used, jumper the terminals 9-12.
It is possible to supply 24Vdc power to the coil of a relay, so as to feed one lamp or more
for a minimum period of 1 second and for a maximum period of 4 minutes (controlled by
the TR trimmer fitted on the EXPANDER card).
The relay is activated at every opening or closing.
When the gate is closed, the traffic light is turned off.
The red light (3-4) turns on when the gate opens.
The green light (5-6) turns on when the gate is open and the red light turns off.
D5
The green light remains turned on until the automatic closing starts.
When the gate closes, the green light turns off and the red light turns on.
D4
When the closing Is finished, the traffic light turned off.
D3
D2
Code ACG5472
APPLICABLE ONLY TO CARDS KS AND KS SUPER WITH SOFTWARE REV 07 OR
LATER
The EXPANDER PLEX card allows the control of up to 4 photocells couples (one
connected to KS card and three connected to the EXPANDER PLEX card).
Control includes a Self Test of the 4 photocells couples and of the fence, performed on
completion of every opening stroke of the gate.
After every opening the gate closure is therefore allowed only upon successful
completion of the 4 photocells couples Self Test.
----> MONITORING OF 4 PHOTOCELLS COUPLES
----> PEDESTRIAN OPENING
----> AUTOMATIC PEDESTRIAN CLOSING
----> MANAGEMENT OF THE SAFETY EDGE
----> MANAGEMENT OF THE COURTESY LIGHT
----> MANAGEMENT OF THE TRAFFIC LIGHT CONTR
----> STRIP CONTROL
AUTOMATIC PEDESTRIAN CLOSING
SAFETY EDGE (11-12)
PHOTOCELL 2 (9-12)
COURTESY LIGHT (7-8)
TRAFFIC LIGHT CONTROL