The garage door opener doesn't operate from either the door control or the remote control:
Does the garage door opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the fuse box
or the circuit breaker. (Some outlets are controlled by a wall switch.)
Have you disabled all door locks? Review installation instruction warnings on page 9.
Are the wiring connections correct? Review Installation Step 5.
Is there a build-up of ice or snow under the door? The door may be frozen to the ground. Remove any restriction.
The garage door spring may be broken. Have it replaced (see page 8 for reference).
The door opener operates from the single button control station, but not from a remote control:
Reprogram the remote control and replace the battery if necessary. Repeat with all remote controls.
The door opens and closes by itself:
Be sure that all remote control push buttons are off.
Remove the bell wire from the single button control station terminals and operate from the remote only. If this
solves the problem, the single button control station is faulty, or there is an intermittent short in the wire. Replace
the control station.
Erase the memory and reprogram all remote controls (refer to the instructions provided with the remote control or
visit LiftMaster.com/Customer-Support).
My remote control will not activate the garage door:
Verify the lock feature is not activated on the door control.
Reprogram the remote control.
If the remote control will still not activate the door check the diagnostic codes to ensure the garage door opener is
working properly.
The remote control has short range:
Change the location of the remote control in your car.
Some installations may have shorter range due to a metal door, foil backed insulation, or metal garage siding.
The door doesn't open completely:
Check power door lock.
Is something obstructing the door? Is it out of balance, or are the springs broken? Remove the obstruction or repair
the door.
The door opens but won't close:
Check that cable tension monitor is correctly installed. If a second cable tension monitor has been removed, follow
the instructions to relearn a single cable tension monitor (See Installation Step 4).
The safety reversing sensor must be connected and aligned correctly before the door opener will move in the down
direction. If you are able to close the door using constant pressure, verify the safety reversing sensors are properly
installed, aligned and free of any obstructions (see page 25).
If the garage door opener lights blink, check the safety reversing sensors (see page 18).
If the garage door opener lights don't blink and it is a new installation see Adjustment Step 1. For an existing
installation, see below.
Repeat the safety reverse test after the adjustment is complete.
The door reverses for no apparent reason and garage door opener lights don't blink:
Check that cable tension monitor is correctly installed. If a second cable tension monitor has been removed, follow
the instructions to relearn a single cable tension monitor (See Installation Step 4).
Is something obstructing the door? Pull the emergency release handle. Operate the door manually. If it is
unbalanced or binding, call a trained door systems technician.
Clear any ice or snow from the garage floor area where the door closes.
Review Adjustment Step 1.
Repeat safety reverse test after adjustments.
My door will not close and the light blinks:
The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the
down direction.
The cable tension monitor must be installed and working properly and the safety reversing sensor must be connected
and aligned correctly before the garage door opener will move in the down direction.
Verify the cable tension monitor is installed and working properly.
Verify the safety sensors are properly installed, aligned and free of any obstructions.
Verify the diagnostic code on the opener and reference the diagnostic chart for further assistance.
Verify the safety sensors are properly installed, aligned and free of any obstructions.