Maintaining And Cleaning; Cleaning; Window And Plastic Cover Cleaning (Pc); Disposal Of Waste Materials - Videotec HGV Manuel D'instructions

Le caisson le plus grand de la gamme
Masquer les pouces Voir aussi pour HGV:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24

7 Maintaining and cleaning

7.1 Cleaning

7.1.1 Window and plastic
cover cleaning (PC)
Surface dirt should be rinsed away with water and
then the window cleaned with a neutral soap diluted
with water, or specific products for spectacle lens
cleaning. These should be applied with a soft cloth.
Avoid ethyl alcohol, solvents,
h
hydrogenated hydrocarbide, strong
acid and alkali. Such products may
irreparably damage the surface.
8 Disposal of waste
materials
This symbol mark and recycle system
n
are applied only to EU countries
and not applied to the countries
in the other area of the world.
Your product is designed and manufactured
with high quality materials and components
which can be recycled and reused.
This symbol means that electrical and electronic
equipment, at their end-of-life, should be disposed
of separately from your household waste.
Please dispose of this equipment at your local
Community waste collection or Recycling centre.
In the European Union there are separate collection
systems for used electrical and electronic products.

9 Technical specifications

9.1 General

Base in aluminium, epoxypolyester powder painting,
RAL9002 colour
Upper body and sunshield in ABS
Stainless steel external screws
Supplied with instruction manual, desiccant bag,
accessories for camera and lens mounting

9.2 Mechanical

Plate with 4xM16 cable glands (in addition a stainless
steel plate is supplied for customized drilling)
Glass window: see drawing
Internal usable area: see drawing
Unit Weight: 9.2kg / 20.2lb

9.3 Electrical

Integrated wiper
- IN 230Vac, consumption 7W max
- IN 24Vac, consumption 7W max
Heater Ton 15°C+/-3°C (59°F +/-5°F) Toff 22°C+/-3°C
(71°F +/-5°F)
- IN 115/230Vac, fan assisted triple heater,
consumption 150W
- IN 24Vac, fan assisted triple heater, consumption 80W
Camera power supply
- IN 100-240Vac - OUT 12Vdc, 50/60 Hz, 1A

9.4 Environment

Indoor / Outdoor
Operating temperature with heater: -20°C / +50°C (-4°F
/ +122°F)

9.5 Certifications

Electrical safety (CE): EN60950-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3
IP protection degree: EN60529 (IP66/IP67, with cable
glands)
EAC certification
9