Anleitung Euro 4000 SPK1
packaging of the processed
Putting the compressor
material, must be observed.
into operation
Additional protective measures
are to be undertaken if
Assembling the wheels (1):
necessary, particularly the
The enclosed wheels must be
wearing of suitable clothing and
assembled in accordance with
masks.
Diagram 1.
● The work room has to be
Make sure that the valve is
bigger than 30 m
3
and have
positioned on the outside.
sufficient ventilation for
1
spraying and drying. Never
spray into the wind.
It is always imperative to
observe the regulations of your
local police authorities when
spraying combustible or
hazardous substances.
● Never process media such as
white petroleum spirit, butyl
alcohol and methylene chloride
with the PVC pressure hose
(reduced life span).
Assembling the rubber buffer
The enclosed rubber stops must
Operation of pressure
be assembled on the supporting
vessels in accordance
foot in accordance with Diagram
with the pertinent
2.
pressure vessel
2
regulations
1. An operator of a pressure
vessel is required to keep the
pressure vessel in good
working order, to operate it
properly, to supervise its use,
to carry out essential
maintenance and repair work
immediately, and to introduce
essential safety measures
Replacing the oil filter and
according to requirements.
installing the air filter (fig. 3)
2. The supervisory authorities
Use a screwdriver to remove the
oil filter plug and insert the
may order essential safeguards
from case to case.
supplied stopper (2) in the
opening.Important! Check the oil
3. A pressure vessel may not be
level.
operated if it has any defects
which constitute a danger to
Changing the air filter:
employees or third parties.
Unscrew the guard hood of the
4. The pressure vessel must be
pushbutton switch (5). The air
regularly inspected for damage,
filter (1) can now be bolted to the
e.g. rust. If you discover any
side of the pump, or
damage, then please contact
disconnected.
the customer service
workshop.
23.11.2006
14:29 Uhr
Seite 11
3
Connecting to the power
supply:
The compressor is equipped with
a mains cable with shock-proof
plug. This can be connected to
any 230V ~ 50Hz shock-proof
socket which is protected by a 16
A fuse. The motor is protected
against overload by a thermal
overload switch. If the rated
current is exceeded, the overload
switch shuts down. After the
overload switch has shut down,
the pressure switch should be
switched off (see Figure 4). After
a short cooling down period, the
overload switch switches itself
back on again.
By pressing the ON/OFF switch
on the pressure switch, the
compressor can be switched on
again. Long supply cables,
extensions, cable reels etc. cause
a drop in voltage and can impede
motor start-up. In the case of low
temperatures below 0°C, motor
start-up is jeopardized as a result
of stiffness.
Explanation of the compressed
air fittings
1 Pressure switch
2 Safety valve
3 Pressure gauge (to indicate the
vessel pressure)
4 Pressure gauge (to indicate the
set pressure)
5 Pressure reducing valve
(pressure setting)
6 On/Off switch
GB