FILLING THE SOLUTION TANK
See Figure 4. Fill the solution tank with a maximum of 70 gallons (264 Liters) of cleaning solution. Do not ll the solution tank above 7.5 cm (3
inches) from the bottom of the Solution Fill (2). The solution should be a mixture of water and the proper cleaning chemical for the job. Always
follow the dilution instructions on the chemical container label. NOTE: EcoFlex machines can either be used conventionally with detergent mixed
in the tank or the detergent dispensing system can be used. When using the detergent dispensing do not mix detergent in the tank, plain water
should be used.
CAUTION!
Use only low-foaming, non- ammable liquid detergents intended for machine application. Water temperature should not
exceed 130 degrees Fahrenheit (54.4 degrees Celsius)
FIGURE 4
3"
(7.5cm)
FIGURE 4.1
SOLUTION SYSTEM INDICATOR (F1):
See Figure 4.1.
- The indicator will light when the solution system is enabled and/or is switched on.
F1
- The indicator will be off when the solution system is off.
- The indicator will ash when the solution tank (liquid level) oat switch senses a low solution level.