Setting The Target Gas; Setting Gas Unit; Switching The Pir Lock On/Off; Factory Default Settings - Dräger Polytron 5000 Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en

Factory default settings

2. Tap [OK]
 The value flashes (data entry mode)
3. Tap [UP]/[DOWN] to scroll through the LEL type
definitions corresponding to the different authorities.
Ptb
Physikalisch-Technische Bundesanstalt
(PTB)
IEC
International Electrotechnical Commission
(IEC)
NI0S
National Institute for Occupational Safety
and Health (NIOSH)
4. Confirm with [OK].
 The value is set and the instrument returns to the
menu.
5. Exit the menu.
 Info - 305 is indicated. Please check the alarm level
set points to ensure safe operation with the new
configuration.

14.3.2 Setting the target gas

®
Polytron
5700 IR only
The target gas can be selected from a list of up to 100 gases
and vapors stored in the gas library of the PIR 7000. For the
list, see the Instructions for Use of PIR 7000 (9023885).
1. Select Gas - set
 The display toggles between the current value and the
menu item.
2. Tap [OK]
 The value flashes (data entry mode)
3. Tap [UP] or [DOWN] to scroll through the gas library.
4. Confirm with [OK].
 The sensor signal of the PIR 7000 is automatically
linearized and temperature compensated for the
selected substance.
 All other parameters for the selected substance (e.g.
measuring ranges etc.) are updated automatically.
 The selected substance is automatically selected as
the calibration gas. During calibration, any substance
listed in the library can be selected as calibration gas.
No manual re-calculation is necessary.
5. Exit the menu.
 Info - 305 is indicated. Please check all settings to
ensure safe operation with the new configuration.

14.3.3 Setting gas unit

Depending on the target gas, the units of measurement can
be switched between ppm, %LEL and Vol%.
1. Select GAS - unit
 The display toggles between the current value and the
menu item.
2. Tap [OK]
 The value flashes (data entry mode)
3. Tap [UP] or [DOWN] to scroll through the units of
measurement.
4. Confirm with [OK].
 The value is set and the instrument returns to the
menu.
5. Exit the menu.
 Info - 305 is indicated. Please check the alarm level
set points to ensure safe operation with the new
configuration.

14.3.4 Switching the PIR Lock On/Off

The PIR Lock function is a special function of the PIR 7x00.
Having the PIR Lock turned on will limit the access to the
parameters of the PIR 7x00.With the PIR Lock on, the Safety
Integrity Level of the PIR 7x00 is SIL 2.
For applications with Safety Integrity Level (SIL) and any
other configuration (if applicable), observe the technical
handbook for the PIR 7x00.
To switch the PIR lock on/off:
1. Select PIR-LOCK-ON/OFF
 The display toggles between the current value and the
menu item.
2. Tap [OK]
 The PIR pin has to be entered.
3. Enter the PIR pin and tap [OK]
4. Set the PIR Lock status.
● Select [UP] to activate the PIR lock status (ON)
 If all settings in the PIR 7x00 are in accordance
with the requirements to achieve SIL operation for
PIR 7x00, this function activates the PIR Lock in
the PIR 7x00 and automatically exits the menu.
● Select [DOWN] to deactivate the display (OFF)
5. Confirm with [OK] and exit the menu.
15
Factory default settings
15.1 Fixed settings for relays, LED and
alarm
Setting
Fault relay
Energized / Normally Open
Yellow Fault LED
Lit if a fault message is available
Red Alarm LED
Single blink if A1 condition is present.
Double blink if A2 condition is
present. If an alarm is configured as
acknowledgeable and the alarm is
acknowledged, single/double blink
changes into continuously lit.
Alarm Hierarchy
A2 overrides A1 on the LED. However,
the A1 and A2 relays operate inde-
pendently. I.e. if A1 is acknowledgeable
and A2 is not, and the gas concentra-
tion is such that it triggers A1 and A2:
acknowledging will cause the A1 relay
to release. However, the red LED will
still double blink as long as the A2 con-
dition continues to exist.
®
Dräger Polytron
5000 Series

Publicité

Table des Matières
loading

Table des Matières