12.5 I nformation requirements for solid fuel local space

heaters

In accordance with EU regulation 2015/1185
Model identifier(s)
Indirect heating functionality [yes/no]
Direct heat output (kW)
Indirect heat output (kW)
Fuel
Wood logs with moisture
content ≤ 25 %
Compressed wood with moisture content
< 12 %
Other woody biomass
Non-woody biomass
Anthracite and dry steam coal
Hard coke
Low temperature coke
Bituminous coal
Lignite briquettes
Peat briquettes
Blended fossil fuel briquettes
Other fossil fuel
Blended biomass and fossil fuel
briquettes
Other blend of biomass and solid fuel
Fuel
Wood logs with moisture
content ≤ 25 %
Characteristics when operating with the
preferred fuel only η
s
Heat output
Nominal heat output P
(kW)
nom
Minimum heat output P
(indicative)
min
(kW)
Useful efficiency (NCV as received)
Useful efficiency at nominal heat output
η
th,nom
Useful efficiency at minimum heat output
η
(indicative)
th,min
Type of heat output/room temperature
control
single stage heat output, no room
temperature control [yes/no]
Other control options
(multiple selections possible)
room temperature control, with presence
detection [yes/no]
room temperature control, with open
window detection [yes/no]
with distance control option [yes/no]
Auxiliary electricity consumption
At nominal heat output el
(kW)
max
At minimum heat output el
(kW)
min
In standby mode el
(kW)
SB
Permanent pilot flame power
requirement
Pilot flame power requirement P
pilot
(if applicable) (kW)
Contact details
LIMA iQ / SILA iQ / SILA PLUS iQ
no
5,5
N.A.
Preferred fuel
Other suitable fuels
yes
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
Space heating emissions
Space heating
at nominal heat output
emissions at minimum
heat output
[x %]
PM OGC CO NO
η
PM OGC CO NO
x
s
≤40 ≤120 ≤1250 ≤200 73,9
[x] mg/Nm
(13 % O
) [x] mg/Nm
(13 % O
3
3
2
73,9 %
5,5
-
84 %
-
yes
no
no
no
0,0012
0,0012
0,001
N.A.
HASE Kaminofenbau GmbH· Niederkicher Str. 14·
54294 Trier
Model identifier(s)
Indirect heating functionality [yes/no]
Direct heat output (kW)
Indirect heat output (kW)
Fuel
Wood logs with moisture
content ≤ 25 %
Compressed wood with moisture content
< 12 %
Other woody biomass
Non-woody biomass
Anthracite and dry steam coal
Hard coke
Low temperature coke
Bituminous coal
Lignite briquettes
Peat briquettes
Blended fossil fuel briquettes
Other fossil fuel
Blended biomass and fossil fuel
briquettes
Other blend of biomass and solid fuel
Fuel
Wood logs with moisture
x
content ≤ 25 %
)
2
Characteristics when operating with the
preferred fuel only η
s
Heat output
Nominal heat output P
nom
Minimum heat output P
min
(kW)
Useful efficiency (NCV as received)
Useful efficiency at nominal heat output
η
th,nom
Useful efficiency at minimum heat output
η
(indicative)
th,min
Type of heat output/room temperature
control
single stage heat output, no room
temperature control [yes/no]
Other control options
(multiple selections possible)
room temperature control, with presence
detection [yes/no]
room temperature control, with open
window detection [yes/no]
with distance control option [yes/no]
Auxiliary electricity consumption
At nominal heat output el
At minimum heat output el
In standby mode el
(kW)
SB
Permanent pilot flame power
requirement
Pilot flame power requirement P
(if applicable) (kW)
Contact details
LIMA iQ+ / SILA iQ+ / SILA PLUS iQ+
no
6,0
N.A.
Preferred fuel
yes
no
no
no
no
no
no
no
no
no
no
no
no
no
Space heating emissions
at nominal heat output
[x %]
PM OGC CO NO
η
x
(≤15) (≤70) (≤500) (≤180) 71,4
[x] mg/Nm
(13 % O
) [x] mg/Nm
3
2
71,4 %
(kW)
6,0
(indicative)
-
81,5 %
-
yes
no
no
no
(kW)
0,0012
max
(kW)
0,0012
min
0,001
N.A.
pilot
HASE Kaminofenbau GmbH· Niederkicher Str. 14·
54294 Trier
en
Other suitable fuels
no
no
no
no
no
no
no
no
no
no
no
no
no
no
Space heating
emissions at minimum
heat output
PM OGC CO NO
s
x
(13 % O
)
3
2
119