iQ technology technical data:
Designation
Operating voltage
Max. power input
Stand-by
Output at nominal heat output
LIMA iQ, SILA iQ, SILA PLUS iQ technical data on:
Output, emissions, and chimney calculation (EN 13384-Part 1/2)
Test bed values*
Nominal Thermal Output
Room heating output
Exhaust gas temperature
Flue Gas Outlet Temp.
Flue Gas Mass Flow Rate
Min. Supply Pressure at Nominal Thermal Output**
Efficiency
CO2 content
CO content
Particulate matter
OGC
NO
X
Min. required combustion air volume
Heatable living space
*at 13% O
2
** The additional supply pressure required for the combustion air connection with the HASE Air System:
at the back= 3 Pa
LIMA iQ / SILA iQ / SILA PLUS iQ stove tested as per DIN-EN 13240 and
Article 15 a B-VG (Austria).
LIMA iQ+, SILA iQ+, SILA PLUS iQ+ technical data on:
Output, emissions, and chimney calculation (EN 13384-Part 1/2)
Test bed values*
Nominal Thermal Output
Room heating output
Exhaust gas temperature
Flue Gas Outlet Temp.
Flue Gas Mass Flow Rate
Min. Supply Pressure at Nominal Thermal Output**
Efficiency
CO2 content
CO content
Particulate matter
OGC
NO
X
Min. required combustion air volume
Heatable living space
*at 13% O
2
** The additional supply pressure required for the combustion air connection with the HASE Air System:
at the back= 3 Pa
LIMA iQ+, SILA iQ+, SILA PLUS iQ+ stove tested as per DIN-EN 13240
and Article 15 a B-VG (Austria).
DIBt approval number: Z-beantragt (FC
118
Value
Unit
5
V
2.5
W
1.0
W
1.2
W
Testing fuel:
Unit
firewood
5,5
kW
5,5
kW
199
˚C
239
˚C
5,5
g/s
12
Pa
84
%
8,8
%
≤ 1250
mg/Nm³
≤ 40
mg/Nm³
≤ 120
mg/Nm³
≤ 200
mg/Nm³
21
m³/h
17-68
m
2
Testing fuel:
Unit
firewood
6
kW
6
kW
235
˚C
291
˚C
5,77
g/s
12
Pa
81,5
%
8,95
%
≤ 500
mg/Nm³
≤ 15
mg/Nm³
≤ 70
mg/Nm³
≤ 180
mg/Nm³
25
m³/h
20-80
m
2
)
61x

12.3 Product data sheet

In accordance with EU regulation 2015/1186
Supplier's name or trade mark
Model identifier
Energy efficiency class
Direct thermal input
Indirect thermal input
Energy efficiency index
Fuel energy efficiency
For assembly, installation and maintenance,
follow the guidelines in the documents
Supplier's name or trade mark
Model identifier
Energy efficiency class
Direct thermal input
Indirect thermal input
Energy efficiency index
Fuel energy efficiency
For assembly, installation and maintenance,
follow the guidelines in the documents
12.4 EC declaration of conformity LIMA iQ / SILA iQ / SILA PLUS iQ
/ LIMA iQ+ / SILA iQ+ / SILA PLUS iQ+
EC declaration of conformity
This EC declaration of conformity applies to LIMA iQ / SILA iQ / SILA PLUS iQ and describes the
conformity with the following directives:
2009/125/EC Directive for the setting of eco-design requirements for energy-related
products (eco-design directive)
In accordance with EU regulation 2015/1185
EC declaration of conformity
This EC declaration of conformity applies to LIMA iQ+ / SILA iQ+ / SILA PLUS iQ+ and describes
the conformity with the following directives:
2009/125/EC Directive for the setting of eco-design requirements for energy-related
products (eco-design directive)
In accordance with EU regulation 2015/1185
LIMA iQ, SILA iQ, SILA PLUS iQ
A+
5,5 kW
0,0 kW
111
84 %
Installation instructions:
LIMA iQ, SILA iQ, SILA PLUS iQ
Operating instructions:
LIMA iQ, SILA iQ, SILA PLUS iQ
Technical data sheet:
LIMA iQ, SILA iQ, SILA PLUS iQ
LIMA iQ+, SILA iQ+, SILA PLUS iQ+
A+
6,0 kW
0,0 kW
108
81,5 %
Installation instructions:
LIMA iQ+, SILA iQ+, SILA PLUS iQ+
Operating instructions:
LIMA iQ+, SILA iQ+, SILA PLUS iQ+
Technical data sheet:
LIMA iQ+, SILA iQ+, SILA PLUS iQ+

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

SilaiqSila plusiqLimaiq+

Table des Matières