4. Connection of Multiple Devices in
Direct Vent Operation
When the Lima, Sila or Sila Plus is operated as a
direct vent model, more than one device can be
connected to the chimney under the following con-
ditions:
CAUTION!
Multiple appliances per chimney are per-
mitted in line with the applicable national
and regional regulations.
All connected fireplace stoves must be in
the same building unit or in the same ef-
fective area of the ventilation system.
The inlets for the combustion air ducts
are located in areas of equal pressure
(same pressure ratios), wind-induced
pressure fluctuations have to be avoided.
The inlets for the combustion air ducts
are located in areas of equal pressure
(same pressure ratios), wind-induced
pressure fluctuations have to be avoided.
NOTE!
In England (UK), according to the appli-
cable building regulations (The Building
Regulations 2010: Combustion appliances
and fuel storage systems, point 1.25),
each solid-fuel appliance is required to
have its own chimney.
40

5. Fuel Load Sizes and Thermal Output

The thermal output depends on the amount of
fuel you put in the stove. When adding more fuel,
please do not exceed the maximum fuel load size
of 2 kg. The fuel can be filled to the maximum
height of 20 cm in the combustion chamber. Ex-
ceeding the maximum fuel load size leads to a dan-
ger of overheating, which can result in damage to
the stove and the risk of a stove fire.
NOTE!
To attain a thermal output of approx. 6
kW, burn wood logs that weigh a total of
1.5 kg and are no longer than 25 cm in
length for about 45 min.
The Lima, Sila or Sila Plus is intended for intermit-
tent operation, please only apply one fuel layer at
a time.

5.1 Wood Briquettes

You can also fuel your Lima, Sila or Sila Plus with
wood briquettes as specified in DIN 51731 Hb2 or
of equal quality. Please note that wood briquettes
swell and expand during combustion. As compared
to the amount of fuel when using logs, reduce the
amount by approx. 10-20% based on the calorific
value of the wood briquettes. The control element
settings and procedure are the same as when
burning logs.

6. Operating the Revolving Console

The Lima, Sila or Sila Plus has a maximum rotational
angle of 120 degrees; you can adjust the rotational
angle in 15-degree increments.
Unlock the rotary console by briefly pressing the
button A and then turn the Lima, Sila or Sila Plus to
the desired position. Shortly before the final position
is reached, press the key A again and lock the stove
into place with a slight rotational movement.
A
fig. 4
WARNING!
Never turn stove when lighting fire!
In the whole rotational area range, the safe
distances (radiation area) apply to distanc-
es to flammable materials.