Technical Data
The Sila Plus, certifi ed in compliance with DIN-EN 13240 and Art. 15 a B-VG
(Austria), can only be operated when the fi re box is closed. Conforms with the
DIBt (Deutschen Institut für Bautechnik/German Institute for Building Technology)
approval criteria for direct vent fi replaces for solid fuels. Multiple connections to the
chimney are possible, see point 4. "Connection of Multiple Devices in Direct Vent
Operation". DIBt approval number: Z-43.12-396 (FC 61x)
The following data applies to the chimney characteristics in accordance with
EN 13384-1 / 2
Combustion Values*
Nominal Thermal Output
Room heating output
Exhaust gas temperature
Effi ciency
Particulate
OGC
NO
X
CO content at 13% O
2
Waste Gas Mass Flow Rate
Waste Gas Outlet Temp.
Min. Supply Pressure at Nominal Thermal Output**
Min. required combustion air volume
* Test bench performance and values
** The additional supply pressure required for the combustion air connection with the Hase Air System:
behind= 3 Pa
Depending on the insulation of the building, the nominal thermal output of 6 kW
indicated on 20 - 80 m² (subject to change).
Dimensions:
Height
Stove
141 cm
Fire box
40 cm
Wood
6
kW
6,4
kW
256
˚C
81
%
16
mg/Nm³
59
mg/Nm³
104
mg/Nm³
1000
mg/Nm³
5,6
g/s
308
˚C
12
Pa
25
m³/h
Width
Depth
47 cm
47 cm
31 cm
28 cm
Weight incl. heat retaining block 141 kg
¹Vertical fl ue pipe length
Flue pipe diameter
Pipe diameter of Hase ventilation system***
Front view Sila Plus:
47
Top view Sila Plus:
*** For separate air supply in low-energy houses and insuffi cient combustion air supply in the room
where the stove is installed.
291 kg
min. 30 cm
15 cm
10 cm
Side view Sila Plus:
13,5 Inst. of Hase air
system below
Dimensions in cm
45