3. Safety Distances

Within a radius of 100 cm in front of and 40 cm
around the stove, flammable, combustible, or heat-
sensitive materials (e.g. furniture, wood or plastic
panelling, curtains, etc.) are not allowed to be loca-
ted in the heat radiating area of the fire box window
(fig. 1).
Behind the stove, outside the area of radiation, a
distance of 15 cm or 12 cm (when situated in a cor-
ner) must be maintained to any flammable materials
(fig. 1).
WARNING!
Flammable flooring materials (e.g. wood,
laminate, carpeting etc.) must be protected
with a floorplate made of non-combustible
material (e.g. tiles, safety glass, slate, or
sheet steel).
The size of the floorplate must be lar-
ger than the base of the stove by at least
60 cm in front and at least 22 cm at the
sides of the stove (fig. 2).
40
fig. 1
Dimensions in cm
22
22
floorplate
60
fig. 2
Dimensions in cm
4. Connection of Multiple Devices in
Direct Vent Operation
When the Luno B.13 is operated as a direct vent mo-
del, more than one device can be connected to the
chimney under the following conditions:
CAUTION!
All connected fireplace stoves must be in
the same building unit or in the same ef-
fective area of the ventilation system.
The inlets for the combustion air ducts are
located in areas of equal pressure (same
pressure ratios), wind-induced pressure
fluctuations have to be avoided.
The inlets for the combustion air ducts are
located in areas of equal pressure (same
pressure ratios), wind-induced pressure
fluctuations have to be avoided.