Installation Conditions And Relevant Building Regulations; Safety Distances; Installation - HASE Ottawa Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.
Installation Conditions and Relevant Building
Regulations
The stove must be installed in accordance with the instructions
and requirements stipulated by the respective national and
European standards and local regulations.
In Germany, the stove must be registered with the local master
chimney sweep for inspection prior to initial operation.
4.

Safety Distances

Within a radius of 80 cm in front of and 40 cm around the
stove, fl ammable, combustible, or heat-sensitive materials
(e.g. furniture, wood or plastic panelling, curtains, etc.) are not
allowed to be located in the heat radiating area of the fi re box
window (Fig. 1).
In regards to fl ammable materials beyond the heat radiating
area, a safety distance of 20 cm at the sides of and behind the
stove has to be adhered to (Fig.1).
WARNING!
Flammable fl ooring materials (e.g., wood,
laminate, carpeting,) must be protected with a
fl oorplate made of non-combustible material
(e.g., tiles, safety glass, slate, or sheet steel).
The size of the fl oorplate must be larger than
the base of the stove by at least 50 cm in front
and at least 21 cm at the sides of the stove
(Fig. 2).
58
20
40
fi g. 1
21
50 fl oorplate
fi g. 2
WARNING!
Never turn stove when lighting fi re!
5.

Installation

Check to make sure that the load-bearing capacity of the
installation surface is suffi cient. If necessary, using a fl oorplate
to distribute the load can increase the load bearing capacity.
Check whether the room in which the Ottawa will be installed
is adequately supplied with enough fresh air. If the windows
and doors are tightly sealed, the necessary supply of fresh
air may not be ensured, which can interfere with the draught
capability of the stove and chimney.
If additional combustion air inlet openings are required, they
are not permitted to be closed or blocked.
Dimensions in cm
CAUTION!
Simultaneous operation of the stove with
ventilation systems and/or exhaust hoods can
cause negative pressure to build up in the
room where the stove is installed, which can
lead to problems such as fl ue gas escaping
21
from the stove.
NOTE!
To ensure that air is not drawn out of the room
where the stove is installed, we recommend
using a window contact switch to lock exhaust
hoods that guide the air to the outside.
Dimensions in cm