3. Safety Distances

The indicated safety distances apply to flammable
materials or materials with flammable parts with a
thermal resistance of R ≤ 6 m²k/W.
For particularly temperature-sensitive materials like
glass, larger distances may be necessary.
Within a radius of 60 cm in front of and 40 cm
around the stove, flammable, combustible, or heat-
sensitive materials (e.g. furniture, wood or plastic
panelling, curtains, etc.) are not allowed to be lo-
cated in the heat radiating area of the fire box win-
dow (fig. 1).
Behind the stove, outside the area of radiation, the
following safety distance to flammable materials
has to be complied with (fig. 1):
Sendai 135 = 16 cm
A
Sendai 175 = 10 cm
B
No flammable or temperature-sensitive materials
may be present within a radius of 20 cm around
the flue pipe connection (wall or room ceiling).
Above the stove, the following safety distances
to flammable materials have to be complied with
(fig. 2).
WARNING!
Flammable flooring materials (e.g., wood,
laminate, carpeting,) must be protected
with a floorplate made of non-combustible
material (e.g., tiles, safety glass, slate, or
sheet steel).
The size of the floorplate must be larger
than the base of the stove by at least
50 cm in front and at least 27 cm at the
sides of the stove (fig. 3).
All manuals and user guides at all-guides.com
A
B
16
10
40
43º
60
40
43º
60
fig. 1
40
fig. 2
40
27
floor-
plate
fig. 3
27
50
Dimensions in cm