Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17

3. Safety distances

The following safety distances* are minimum values
which must be observed to ensure fire safety.
Observe the following safety distances
(Fig. 2-4) for flammable materials:
c
c
b
b
Fig. 2
Safety distances from
Abbreviation
flammable materials
Front of stove
a
Side of stove
b
Back of stove
c
Ceiling/top edge of stove
d
Flue pipe connection
e
*Depiction of safe distances without rotary function.
** The safety distance is defined by the flue pipe manufacturer.
If not values are specified, the relevant Ordinance on Firing
Installations applies.
Fig. 3
When setting the stove up on flammable flooring
(e.g. wood, laminate, carpet) a floorplate (e.g. safety
glass, steel, stone) must be used (Fig. 5):
g
Fig. 4
Dimensions
Floorplate safety
[cm]
distances
100
Front of floorplate
45
Side of floorplate
12
The safety distances specified also apply for highly-
75
insulated components with a thermal insulation
resistance of R ≤ 8 m²K/W (Fig. 2,3: b,c).
**
Fig. 5
Abbreviation
Dimensions
[cm]
f
50
g
24
39
en

Publicité

Table des Matières
loading

Table des Matières