HASE OSAKA Manuel D'utilisation page 45

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Stove:
Abbrevi-
Designation
ation
a
Height
b
Width
c
Depth
Firebox:
-
Height
-
Width
-
Depth
Connections:
d
Distance from rear stove wall - flue pipe centre
e
Flue pipe diameter*
f
Flue pipe connection height
g
External air supply, bottom connection height
/ Ø**
h
External air supply, rear connection height / Ø**
*for separate air supply in low energy houses and building ventilation
**HASE air system pipe diameter
Weights:
Stove type
Cladding
OSAKA
Ceramic
OSAKA technical data on:
Output, emissions, and chimney calculation (EN 13384-Part 1/2)
Test bed values*
Dimensions [cm]
147
Nominal Thermal Output
45
Room heating output
45
Exhaust gas temperature
Flue Gas Outlet Temp.
Flue Gas Mass Flow Rate
44
Min. Supply Pressure at Nominal Thermal Output**
25
Efficiency
27
CO2 content
CO content
22,5
Particulate matter
15
OGC
135
NO
13,5 / 10
X
Min. required combustion air volume
10 / 10
Heatable living space
*at 13% O
** The additional supply pressure required for the combustion air connection with the HASE Air System:
at the back= 3 Pa
Weight [kg]
187
2
Testing fuel:
Unit
firewood
5
kW
5,5
kW
234
˚C
281
˚C
4,4
g/s
12
Pa
84
%
10,4
%
≤ 1250
mg/Nm³
≤ 40
mg/Nm³
≤ 120
mg/Nm³
≤ 200
mg/Nm³
21
m³/h
15-60
m
2
45
en

Publicité

Table des Matières
loading

Table des Matières