7.7. Cleaning the generating set
Cleaning with a water jet is not recommended.
Cleaning with high pressure cleaning equipment is forbidden.
Important
Remove all dust and debris from around the exhaust.
Clean the generating set, particularly the alternator and engine air inlets and outlets, using a cloth and brush.
Check the general condition of the generating set and replace any faulty parts.

8. Storing the generating set

In the event that the generating set is not to be used for a long period, it must be stored in accordance with the guidelines below.
Open the fuel tap (diag. D - no. 6) and drain the fuel from the tank into a suitable container.
Switch on the engine until it runs out of fuel.
While the engine is still warm, change the engine oil (see the Changing the engine oil section).
Run the engine for 2 to 3 seconds with the decompression lever (diag. D - no. 7) set in the non-compression position and the
on/off key (diag. B - no. 1) in the on position [position (A)].
Do not start the engine.
Allow the decompression lever to return to the top, then slowly pull the starter-recoil reel handle (diag. B - no. 2) until there is some
resistance .
Clean the generating set and cover it with a protective cover to protect it from dust.
Store the generating set in a clean, dry place.

9. Troubleshooting

Problems
Load connected to the generating set during start-up.
The air filter is clogged.
The fuel tap is closed.
The fuel level is too low.
The engine does
not start
The fuel filter is clogged.
The oil level is too low.
The fuel supply is blocked or leaking.
Faulty battery.
The ventilation inlets are blocked.
Engine stoppage
The fuel level is too low.
The oil level is too low.
The circuit breaker(s) is tripped.
Faulty appliance supply lead.
No electric
current
Defective electrical socket.
Faulty alternator.
The device is connected or the lead is defective.
Circuit breakers
engaged
Overload (cf. see Generating set capacity section).
Probable causes
Possible solutions
Disconnect the load.
Clean the air filter (see the Cleaning the air filter
section).
Open the fuel tap (diag. D – no. 6).
Top up the fuel (see the Filling with fuel section).
Clean the fuel filter (see the Cleaning the fuel filter
section).
Check the oil level and top up if necessary.
Have it checked, repaired or replaced.*
Recharge or replace the battery.
Clean the air inlet and outlet guards.
Top up the fuel (see the Filling with fuel section).
Check the oil level and top up if necessary.
Engage the circuit breaker(s) (diag. A – no. 11).
Replace the lead.
Have it checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Disconnect the device and the lead.
Remove the excess load.
* Operation(s) must only be carried out by one of our agents.