Configuration of unit software

You can connect the unit to the battery via the lorry's terminal block or directly.
The terminal block is to be preferred for the connection. Ask your vehicle manu-
facturer for the specifications of the terminal block.
➤ Lay the supply line and connect it to the vehicle (red line to plus, black line to
minus).
7
Configuration of unit software
Before you first start up the unit, the controls can be adapted to suit the
installation conditions. This must be done by the person installing the unit.
In configuration mode, the following unit software parameters must be set at the
control panel (fig. b, page 8).
Menu
Parameter
level
1
Set temperature
2
Low voltage
cut-off
3
Operating mode The unit starts with the operating mode
4
Default settings
5
Temperature unit
display
I
NOTE
Configuration mode can still be activated if the undervoltage protection
mechanism has switched off the unit and only residual voltage is available.
24
Meaning
The unit starts at the temperature
defined here.
The battery monitor shuts down the unit
at the voltage defined here.
defined here.
Parameters 1 – 3 can be reset to the
default settings.
The temperature can be displayed in °C
or °F.
CoolAir SP950I
Default
setting
20 °C (68 °F)
Characteristic
figure 4 =
22,8 V
0 = Auto-
matic mode
--
°C
EN