Configuration of unit software

7.8

Fastening the cover frame

A
NOTICE!
Screw the screws in carefully order not to damage the cover frame.
fig. 8, page 7
➤ Fasten the cover frame (6) to the unit with the four cylindrical screws
(M6 x 60 mm) (8), washers (7) and the four spacer sleeves L = 48 mm (5). The
spacer sleeves keep the cover frame apart from the unit.
8
Configuration of unit software
Before you first start up the unit, the controls can be adapted to suit the
installation conditions. This must be done by the person installing the unit.
In configuration mode, the following unit software parameters must be set at the
control panel (fig. 9, page 7).
Menu
Parameter
level
1
Set temperature
2
Low voltage
cut-off
3
Operating mode The unit starts with the operating mode
4
Default settings
5
Temperature unit
display
I
NOTE
Configuration mode can still be activated if the undervoltage protection
mechanism has switched off the unit and only residual voltage is available.
20
Meaning
The unit starts at the temperature
defined here.
The battery monitor shuts down the unit
at the voltage defined here.
defined here.
Parameters 1 – 3 can be reset to the
default settings.
The temperature can be displayed in °C
or °F.
CoolAir RT780
Default
setting
20 °C (68 °F)
Characteristic
figure 4 =
22,8 V
0 = Auto-
matic mode
--
°C
EN