Télécharger Imprimer la page

Cleaning And Maintenance - Arktic 232118 Mode D'emploi

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
7.7. ALARMS
Alarm
P1
P2
HA
LA
EA
CA
dA

8. CLEANING AND MAINTENANCE

CAUTION: Before cleaning and/or maintenance make sure that the appliance is NOT connected to the
power supply. The maintenance of the appliance should be performed by qualified and certified per-
sonnel.
8.1. CLEANING
Trouble-free operation and service life of the appli-
ance are essentially dependent on the proper main-
tenance according to the schedule. Daily cleaning of
the cooling/freezing chamber is essential to prevent
bacterial growth. Before cleaning, manually defrost
the appliance with the door open and the drain plug
removed. Follow the instructions below:
• Do not use direct water jet and water under pres-
sure to clean the appliance as it can damage the
electrical wiring.
• Do not use any metal objects to remove ice ac-
8.2. CLEANING OF THE CONDENSER
Before cleaning of the condenser make sure that
the appliance is NOT connected to the power sup-
ply. To ensure a trouble-free and long-term oper-
ation of the condenser unit it is necessary to clean
the condenser at least once a month. Use a brush
with long bristles for condenser cleaning. It is rec-
ommended to wear protective gloves during clean-
ing of the condenser - it reduces the risk of injury
8.3. MAINTENANCE
Remember to check the technical condition of the
appliance regularly (at least once a year) - the over-
haul should be carried out by qualified and licensed
personnel.
Check whether:
Error
Chamber sensor error
Evaporator sensor error
Maximum temperature alert
Minimum temperature alert
External alert
Severe external alert
Door opened
cumulated inside the chamber as it may scratch
and/or damage its internal surfaces.
• Always use lukewarm (not hot!) water with a mild
detergent for cleaning and a soft cloth for drying
of the appliance.
• Avoid using corrosive substances that contain
chlorine (and its solutions), caustic soda, hydro-
chloric acid, acetum, bleach etc.
It is recommended to wear protective
gloves during cleaning of the appliance.
and cutting with its sharp edges. Dirty condenser
unit reduces motor power which increases power
consumption of the appliance.
Take care not to damage the cooling system.
It is recommended to wear protective
gloves during cleaning of the appliance -
risk of injury.
• The condensate drainage system operates
properly.
• There is no refrigerant or freezing agent leak-
age and whether the cooling system operates
properly.
EN