Télécharger Imprimer la page

Bartscher F80 Manuel De Service page 71

Masquer les pouces Voir aussi pour F80:

Publicité

Les langues disponibles

Les langues disponibles

K Change of the driers
1 For the F 125 Model front/upper and the
side/back plate
2 Remove the cooling agent from the system
and let it flow into a particular container,
which can be later recycled after a corre-
sponding cleaning.
3 The cooling agents guides from both ends
(for the F 125 Model, weld the capillary tube
on a side of the drier).
4 Remove the seals to both ends for the moun-
ting of the new driers and wearing the pipes
of the cooling agent.
5 Carefully rinse the cooling agent circulation
for humidity and remove the non-condensa-
ble gases after installing the new driers.
6 Fill the cooling agent circulation with the right
amount of cooling agent (see type) and exa-
mine, whether appearances* with the level
smelted* places are available.
7 Mount the previously removed plate again.
L Change of the evaporator
1 Follow the instructions of Point H for the
removal of the ice discharge opening.
2 Remove the *shell of the connection of the
water entry* in the evaporator and draw out
the *pipe. Empty the water found in a con-
tainer.
3 Pull out the sensor pipe of the evaporator as
in Point B.
4 Remove the cooling agent from the system
and let it run into a particular container, so
that it can be recycled later after a corre-
sponding cleaning.
5 Welding and separate the capillary tube and
the collection/sucking unit from the outflow
pipe of the evaporator.
6 Loosen the three-four bolts, which are used
to fasten the evaporator on the upper casing
of the gear motor.
7 Remove the evaporator of the gear motor
and if necessary, remove the aluminum con-
tainer* by loosening the three-four bolts of
the evaporator.
NOTE. Replace the dryer filter whenever the
refrigerant circuit is opened. Do not apply the
new filter dehumidifier until all repairs or repla-
cements have been made.
8 For the installation of the new evaporator the
process used in a reverse order.
NOTE. Carefully purged the refrigerant circuit
to remove moisture and non-condensable
gases after the replacement of the evaporator.
M Change of the air-cooled condenser
5 For the F 125 Model the front/upper and the
side/back plate
2 Remove the sensor pipe from the cooling
bulb of the condensers.
3 Loosen the bolts, which are used to fasten it
on the base/frame.
4 Remove the cooling agent from the system
and let it flow into a particular container, to be
able to recycle it later after the corresponding
cleaning.
5 Weld the cooling agent pipes from both
ends.
NOTE. Replace the dryer filter whenever the
refrigerant circuit is opened. Do not apply the
new filter dehumidifier until all repairs or repla-
cements have been made.
6 For the installation of the new condensers,
use the process in a reverse order
NOTE. Carefully purged the refrigerant circuit
to remove moisture and non-condensable
gases after the replacement of the condenser.
GB
29

Publicité

loading

Ce manuel est également adapté pour:

F125104409104436