12 Press and remove the Super Flakes Ice Model
with the sheets, from two screws pulled from the
lower edge of the brass rings of the lower sto-
rage casing.
NOTE. Is a good practice to replace both the
ring of the mechanical seal that the bearings,
upper and lower, as well as O-rings each time
it is disassembled the evaporator assembly.
For this purpose there is a kit of these parties
also accompanied by a tube of grease food
and water repellent.
13 Pull the components of the drive coupling from
aluminum container out.
14 Control the state of both half couplings.
Immediately exchange if there is wear and tear.
15 Install the lower storage in its bronze casing
and put it in such a way that the white plastic
ring shows on the top.
16 Install the upper storage of the icebreakers.
The flat part starts with the radial part.
The surfaces must be mounted upward.
17 Lubricant (grease) on the upper part.
Then mount the roll cage with the smaller ope-
nings at the top, to allow a little movement
between the plastic cage and the flat surfaces
of the lower storage part (see diagram).
18 Grease and then mount the equalizing disc
made of steel
19 After changing the O-Ring seal in the ice-
breaker, install the icebreaker on top of the
screw and fasten it with the upper bolt.
20 Install the screw icebreaker unit in the evapora-
tor. Use the previous points in a reverse order.
28
I Change of the gear motor
1 For the F125 Model the front/upper and the
side/back plate
2 Loosen the three-four screws, which are
used to fasten the evaporator on the upper
casing.
3 Remove the sensors for the engine rotating
direction according to the instructions in
Point B.
Loosen the screws which are used to fasten
the gear motor on the framework.
4 Interruption of the supply of power of the
motor through the electrical equipment. The
gear motor is now released and can be exre-
verse
5 To install the new gear motor, use the process
in the reverse order.
J Change of the ventilator
1 For the F125 Model the front/upper and the
side/back plate
2 Loosen the nuts and search and pull out the
yellow/green grounding cable. The mandrel
for the connection of the electrical cable of
the ventilator.
3 For the F 125 Model, loosen the bolts which
are used to fasten and take out the ventilator
unit on the base of the device.
NOTE. When installing a new fan motor check
that the blades do not touch anything and turn
freely.