MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Disconnect the device from the power supply before carrying out any maintenance operation.
1 Frequently check the installation in order to detect
any imbalance or sign of deterioration or wear. Do
not use the device if any repair or adjustment is
necessary.
2

FAILURE DIAGNOSIS

Diagnosis LEDs and fuses
P1 P2 P3
P4 P5 P6
ST1
FT1
ST2
SW1 Main switch
F1
M1 Motor fuse
M101: 2.5A (230Vac/50Hz)
M101M: 4A (125Vac/60Hz)
F2
Electronic fuse (0.5A)
F3
Output fuse 24Vac (315mA)
DL1 - DL3 flashing: STOP contact open
(emergency stop activated)
DL1
Gate totally or partially open
DL2
Receiving RSD plug-in receiver radio signal
(RUN/OK)
DL3
Radio code or operation programming
DL4
Opening relay activated
DL7
DL8
P7 P8
P15 P14 P16
P11 P12
P22 P23
24Vac
LOCK
FT2
FCA1
FCC1
STOP
2 Check that the operation and safety devices
(photocells or strips), as well as their installation,
have not suffered any damage from the weather or
external agents.
G7 G8
G9 G10
Courtesy
Lamp.
MOTOR1 (G2-G1-COM)
Light
DL5
Closing relay activated
DL6
Interior safety device contacts (FT2) closed
DL7
FCA contacts closed
DL8
FCC contacts closed
DL9
Exterior safety device contacts (FT1) closed
DL10 Pedestrian key command (ST2)
DL11 Total key command (ST1)
DL12 Plug-in receiver key command (except RSD)
DL13 Garage light relay activated
DL14 Power supply
DL15 Electrolock relay activated
DL17 Triac M1 activated
G1
G2
G3
N
L
POWER
E170D
Control board VIVO-M101(M)
English
53