ELECTRICAL CONNECTIONS

Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, always earthed.
Check the manufacturer's instructions for all the elements installed.
Power supply and motor connections
P1 P2 P3
ST1
FT1
A1
operator
C1
capacitor
DL4
open indicator
DL5
close indicator
PUL1
close mini-pushbutton
PUL2
open mini-pushbutton
T
earth connection
When pressing PUL1 (close), DL5 lights up and the G2 and G3 cable connectors are activated.
When pressing PUL2 (open), DL4 lights up and the G1 and G3 cable connectors are activated.
P4 P5 P6
P15 P14 P16
P7 P8
P11 P12
P22 P23
G7 G8
Courtesy
24Vac
ST2
FT2
FCA1
FCC1
STOP
LOCK
Light
G1
G2
G3
G9 G10
N
L
POWER
Lamp.
MOTOR1 (G2-G1-COM)
G1 G2 G3
A1 operator connections
G1
open
G2
close
G3
common (COM), grey cable
INSTALLATION
VIVO-M101: 230Vac/50Hz
VIVO-M101M: 125Vac/60Hz
P170V
Control board VIVO-M101(M)
45