PROGRAMMING AND STARTUP

1

CONTROLS AND COMMANDS

P1 P2 P3
P4 P5 P6
P15 P14 P16
ST1
FT1
ST2
FT2
FCA1
Operation
Pedestrian
SW2 functions
Functions during programming (DIP1=ON)
DIP2=ON: total opening run programming (see page
page 50)
DIP3=ON: pedestrian opening run programming (see
page page 51)
DIP4=ON: total opening radio code programming (see
page 49)
DIP6=ON: pedestrian opening radio code
programming (see page 49)
Functions during use (DIP1=OFF)
DIP2: advance warning
DIP2=ON: the light lights up and the operation
begins after a 3 second warning.
DIP2=OFF: the light lights up and the operation
begins immediately.
DIP3: step-by-step or community opening mode
DIP3=ON: step-by-step opening (the control
board obeys the key device during opening).
DIP3=OFF: collective opening (the control
board does not obey the key device during
opening).
48
Installation Manual
Close Open
G1
G2
G3
P7 P8
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
LOCK
24Vac
Lamp.
FCC1
STOP
MOTOR1 (G2-G1-COM)
Light
SW1
Main switch
SW2
Programming DIPs
ST1
Total operation mini-pushbutton
ST2
Pedestrian operation mini-pushbutton
PUL1 Close mini-pushbutton
PUL2 Open mini-pushbutton
T.LG
Garage light time regulation
T.E.
Standby time regulation (only works in
automatic mode)
P.M.
Torque adjustment (maximum thrust) and
sensitivity adjustment in obstacle detection (only
with DIP9=ON and electromechanical
operators)
N
L
POWER
P171C
DIP4: automatic or step-by-step closing mode (in
pedestrian and total operation) (only with
DIP10=OFF)
DIP4=ON: automatic mode (the gate closes
automatically after standby time has passed, which is
adjusted using T.E.).
DIP4=OFF: step-by-step mode (the gate only
closes when receiving the key command).
DIP5: back pulse/close pulse
DIP5=ON: back pulse activated. Should soft stop
be selected (DIP8=ON), a close pulse is also made.
DIP5=OFF: close and back pulse disabled.
DIP6: automatic closing mode optional (with
DIP4=ON only)
DIP6=ON: during standby, the gate obeys the
key device (this can be closed before standby time
finishes).
DIP6=OFF: the gate cannot be closed until
standby time finishes.
DIP7: maintain hydraulic pressure (for hydraulic
operators only)
DIP7=ON: maintain hydraulic pressure activated.
A close pulse is sent every half an hour as of the last
operation.
DIP7=OFF: maintain hydraulic pressure disabled.
DIP8: slow down function
DIP8=ON: the gate reduces its speed before
reaching the stopper.
DIP8=OFF: the leaf reaches the stopper at high
speed.