Selection Of Control Board Functions And Modes (Sw2); Potentiometer Adjustment; Start Up - Erreka VIVO-M101 Manuel De L'installateur

Masquer les pouces Voir aussi pour VIVO-M101:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROGRAMMING AND STARTUP
6

SELECTION OF CONTROL BOARD FUNCTIONS AND MODES (SW2)

Using SW2, choose the required options (see "SW2 functions" on page 48).
7

POTENTIOMETER ADJUSTMENT

8

START UP

Final checks
Following installation and programming, start up the
operator and check the devices installed:
1 Check the correct working of the key devices (push
button, key switch, transmitter).
See "Functioning modes" on page 41.
2 Check the correct operation of the safety devices
(photocells or mechanical strips).
See "A- Detection by additional safety device
(photocell or mechanical strip)" on page 42.
3 Place an obstacle and make the gate collide with it
in order to check operation in the event of collision.
See "B- Direct detection (built-in safety):
operator model VULCAN VUS (DIP12=ON)" on
page 42.
4 If everything is correct, close the control board
cover.
52
Installation Manual
P1 P2 P3
P4 P5 P6
P15 P14 P16
P7 P8
P11 P12
ST1
FT1
ST2
FT2
FCA1
FCC1
STOP
LOCK
P171M
Garage lighting time (T.LG)
If the garage lighting circuit has been connected to the
control board, regulate the time which the lamps shall
remain on using T.LG.
Minimum value: 3 seconds; maximum value: 90
seconds.
Open gate standby time (T.E.)
If automatic operation mode has been programmed
(DIP4=ON), adjust T.E. to adjust standby time with the
gate open (before automatic closing begins).
Minimum value: 3 seconds; maximum value: 60
seconds.
Torque regulation (P.M.)
Correct
torque
importance to prevent injury and damage.
Increased torque produces a more violent
P22 P
impact.
24Va
• Hydraulic operators: set P .M. at the maximum
value.
• Electromechanical
detection sensitivity to be adjusted (DIP9). Set P.M
at the minimum value possible, compatible with the
proper operation of the gate.
If the system does not work correctly, find out
why and put it right (see section "Failure
diagnosis" on page 53).
User instruction
1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the instructions on use.
2 Signpost
the
automatically and indicating how to operate it
manually.
Where
operation is using the remote control.
adjustment
is
of
operators:
allows
gate,
showing
that
it
appropriate,
indicate
vital
obstacle
opens
that