Installation; Required Tools; Initial Conditions And Checks; Securing The Elements - Erreka VIVO-M101 Manuel De L'installateur

Masquer les pouces Voir aussi pour VIVO-M101:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION

1

REQUIRED TOOLS

Set of screwdrivers
Marker pencil
Tape measure
2

INITIAL CONDITIONS AND CHECKS

Initial installation conditions
Ensure the operator is correctly installed in the
gate.
Environmental conditions
This device is not suitable for installation in
inflammable or explosive environments.
Electrical power supply installation
Ensure the direct current connection and
installation fulfil the following requirements:
• The nominal voltage of the installation must
coincide with that of the control board.
• The installation must be able to support the
power consumed by all the automatic key
devices.
• The installation must be earthed.
3

SECURING THE ELEMENTS

1 Choose a location for the control board, taking as a
reference the figure shown in "Elements of the
complete installation" on page 39.
The height from the ground must be
sufficient as to be out of the reach of children.
The attachment surface must resist the
weight of the control board.
2 Make two holes and attach the control board with
appropriate screws.
44
Installation Manual
Electrical drill and broaches
Use the electrical drill in line with the user
manual.
An earthed power supply of 230Vac, 50Hz
(VIVO-M101) or 125Vac, 60Hz (VIVO-M101M) is
required.
Check that the admissible environmental
temperature range for the control board is
suitable for the location.
• The electrical installation must comply with
low voltage regulations.
• The installation elements must be properly
secured and in a good state of conservation.
• The direct connection point must be high
enough to be out of the reach of children.
If the electrical installation does not comply
with the foregoing requirements, repair before
installing the automatic key device.
3 Attach the other elements of the installation in line
with the corresponding instructions.
4 Position the ducts for the cable, securing them firmly
using appropriate means.
If pushbuttons are installed to operate the
facility, we recommend installing them out of
the reach of children (minimum recommended
height 1.6 m).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-m101m

Table des Matières