Filtration Group MFS-E900 Traduction Du Mode D'emploi Original page 34

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.1
Explosion protection
Danger of explosion!
Risk of serious or fatal injury.
 The Filtration Group filter controller must
not be installed or operated in potentially
explosive atmosphere.
A special control cabinet must be used if automatic filters
are operated in potentially explosive atmosphere.
 Please ask your Filtration Group contact for more
information.
The E900 must be equipped with cut-off relays in order to
control automatic filters in hazardous areas (see diagram
below).
Safe
area
= Pneumatic line
= Electrical line
Fig. 4:
Installation of the controller if filters are
installed in a hazardous area
Page 6
Translation of the original instructions MFS-E900, Filtration Group GmbH, 26.09.19, Mat. No. 72370026, Version 05
DANGER!
Hazardous
area
8
Transport and storage
Transport
 Always transport horizontally in the original packaging.
 Avoid vibration.
Storage
 Always store horizontally in the original packaging.
 Always store in a dry, frost-free room.
9
Electrical connections
Danger of electric shock!
Risk of serious or fatal injury in case of
contact with electrical components.
 All electrical installation work must be
carried out by a qualified electrician!
 Do not install in the vicinity of devices that are
susceptible to interference.
 Do not install in the vicinity of electromagnetic
interference sources (power cables).
 Height in conformity with DIN EN 60204-1.
 The main switch, the customer's emergency stop buttons
and all other control elements must be easily accessible.
9.1
Power supply
 Switch off the main switch.
 Feed the power supply and valve cables into the housing
through the fitting.
 Connect the power supply and valve cables to the
terminals provided for this purpose.
To select the input voltage
To select the input voltage, detach the
power supply from the mounting rail and
set the switch (Input Select Voltage) to the
required voltage.
Fig. 5: Selecting the input voltage
DANGER!