Mounting in the door frame

If the escape door locking system 352M is mounted in the door frame, the lock
counterpart position can be adjusted 2 mm by changing the alignment using
the SETLA M5 positioning plate (Fig. 4 a, b, c).
The spacer plates can be used to adjust the precise position in 0.5 mm incre-
ments (Fig. 4 d, e and 4).
Fig. 4 does not show all possible combinations between SETLA M5 and spacer
plates. The spacer plates can also be used if the SETLA M5 positioning plate is
installed in the directions a or b.
Setting the rebate gap
The distance between the escape door locking system 352M and the lock counter-
part facing it must be adjusted so that the bolt can be fully extended and en-
gage in the lock counterpart without any backlash.
2 Mount the SETLA M5 positioning plate and the spacer plates as seen in the
examples (Fig. 4 a, b, c, d, e).
3 Check the rebate gap ("Technical data", page 52). The tolerance for
positioning depends on the rebate gap. Use spacer plates if the rebate gap is
too wide (> 4.5 mm).
 The rebate gap is correctly adjusted, the bolt is fully extended and the door is
locked without any play.