Item
Designation
1
On/Off switch
2
Signal light
3
Installation opening for start/stop socket (optional fitting)
(closed with dummy plug)
4
Pressure measurement opening (only for service employees)
5
Signal horn
6
Pressure switch (closed with dummy plug)
(service personnel only)
I/0 switch (item 1)
The product is switched on and off by pressing the switch.
The green control lamp in the switch control panel shows that the product is operating
without malfunctions or shows operational readiness if an optional start-stop sensor is
fitted.
Indicator lamp (item 2)
If the yellow indicator lamp lights, the following faults may have occurred:
Motor protection relay has triggered
Phase error/missing phase
Filter change necessary
Installation opening for start/stop socket (item 3)
Installation opening for the optional equipment of the automatic start/stop system.
Pressure measuring opening (item 4)
Connection facility for our service department. Our service department can take
pressure measurements using this connection.
NOTE
Signal horn (item 5)
Reliable capture of welding fumes is only possible with sufficient extraction capacity.
As the dust accumulation in the filter increases, its flow resistance increases and the
1502818-00