Télécharger Imprimer la page

geo-FENNEL FET 220K-L Mode D'emploi page 21

Publicité

Les langues disponibles

Les langues disponibles

MODE CONVERSION OF THE HORIZONTAL RIGHTWARD (HR) AND LEFTWARD (HL)
TURNING INCREMENT
Standardly the horizontal angle mode is clockwise (display indication HR).
Press R/L to transform the horizontal angle mode to anti-clockwise (display indication HL).
The key R/L is of no effect to the vertical angle.
Press R/L again to transform the mode from HL to HR.
HORIZONTAL ANGLE LOCKED - UNLOCKED (HOLD)
·
Press HOLD; the horizontal angle reading will flash.
·
Keep HOLD pressed for 3 seconds.
·
Now the horizontal angle reading is locked and the reading stops flashing.
·
Press HOLD again to quit this mode / release the value.
SLOPE PERCENT MODE (%)
·
Press V/% to switch the vertical angular reading shown in degrees into percent reading.
·
The maximum % value will be 99.999 %; exceeding this the display will show ---,---- %
ANGULAR REPEATED MEASUREMENT
·
Press SFT + REP to start this mode.
·
T1 will flash in the display.
·
Aim at the first target and press 0SET; the horizontal reading will set to 0.
·
T2 will flash in the display.
·
Aim at the second target and press HOLD; display line 2 will show the average of the horizontal
readings, display line 1 will show the number of repeated measurements.
·
T1 will flash in the display; now you can aim again at the first target and all following steps can be
repeated as above.
·
Press SFT to quit this mode.