4.
Display of parameters currently set as well as data
for the switchgear (type, serial number etc.)
5.
Basic settings for the switchgear
6.
Fault memory
7.
Service menu (can only be activated by Wilo
customer service)
The menu structure is adapted automatically
based on the signal transmitters used. Menu
1.2.2.0 is only visible for instance if a level sensor
is connected and activated accordingly in the
menu.
6.4.1. Menu structure
1.
Start the menu by pressing the operating knob
for 3 sec.
2.
Choose the selected menu: Easy or Expert.
3.
Follow the menu structure below for the desired
value and change this according to your specifi -
cations.
Menu 1: Control parameters
No.
Description
1.1.0.0 Operating mode
Selection:
1.1.1.0
empty
fi ll
1.2.0.0 Control values
Threshold for activation/deac-
1.2.2.0
tivation level (only available if a
level sensor is used)
Base-load pump on
1.2.2.1
Value range: 0.09 to 12.45
Factory setting: 0.62
Base-load pump off
1.2.2.2
Value range: 0.06 to 12.42
Factory setting: 0.37
Peak-load pump 1 on
1.2.2.3
Value range: 0.09 to 12.45
Factory setting: 0.75
Peak-load pump 1 off
1.2.2.4
Value range: 0.06 to 12.42
Factory setting: 0.50
Peak-load pump 2 on
1.2.2.5
Value range: 0.09 to 12.45
Factory setting: 1.00
Peak-load pump 2 off
1.2.2.6
Value range: 0.06 to 12.42
Factory setting: 0.75
Peak-load pump 3 on
1.2.2.7
Value range: 0.09 to 12.45
Factory setting: 1.25
42
Menu 1: Control parameters
No.
Peak-load pump 3 off
1.2.2.8
Value range: 0.06 to 12.42
Factory setting: 1.00
Delay times for activation and
1.2.5.0
deactivation of the pumps
Base-load pump stop delay
1.2.5.1
Value range: 0 to 60
Factory setting: 5
Peak-load pump(s) activation
delay time
1.2.5.2
Value range: 1 to 30
Factory setting: 3
Peak-load pump(s) stop delay
1.2.5.3
Value range: 0 to 30
Factory setting: 1
Display
Stop delay at dry-running level
1.2.5.4
Value range: 0 to 10
Factory setting: 0
Activation delay time after dry
run
1.2.5.5
Value range: 0 to 10
Factory setting: 1
System activation delay time
after power interruption
1.2.5.6
Value range: 0 to 180
Factory setting: 0
Menu 2: Communication parameters
No.
2.0.0.0 Communication
Field bus
Values: None, Modbus, BACnet,
2.1.0.0
GSM
Factory setting: None
Menu 3: Pump activation
No.
3.0.0.0 Pump activation
Switching automatic mode on/
off
3.1.0.0
Values: ON, OFF
Factory setting: OFF
3.2.0.0. Operating mode per pump
3.2.x.0 Selection of pump 1 ... 4
OPERATION AND FUNCTION
Description
Display
Description
Display
Description
Display
WILO SE 05/2016 V05 DIN A4