TROUBLESHOOTING
Problem
Cause
Wrench does not
No battery
turn on when
installed/ battery
power button is
is not charged
pressed.
Firmware Issue
Torque reading is
Calibration
out of specifi cation.
required
Wrench settings
Battery was
were not saved
removed before
once battery was
the setting was
removed.
saved.
Torque zero error
Torque applied
while zeroing.
Wrench is over
torqued.
Wrench was not
calibrated
correctly.
Failure to the
torque sensor.
Overtorque
125% of the max
torque rating has
been applied to
the tool.
Torque overload
150% of max
torque rating has
been applied to
the tool.
Display memory
Memory failure
error.
Display torque
Torque is
uncalibrated.
uncalibrated.
Display warning
Tool needs
attention.
Display battery
Wrench has
over temperature
exceeded peak
temperature while
running.
Display
Tool will exceed
certifi cation
the expiration
needed soon.
date for
certifi cation soon.
470 221 - M12 ONEFTR38, M12 ONEFTR12.indd 19
470 221 - M12 ONEFTR38, M12 ONEFTR12.indd 19
Display out of
certifi cation.
Solution
Insert / Replace
battery
Turn tool OFF and
remove battery
Return to a service
BATTERIES
center to be
Battery packs which have not been used for some time
calibrated.
should be recharged before use.
Return to a service
Temperatures in excess of 50°C (122°F) reduce the
center to be
performance of the battery pack. Avoid extended exposure
calibrated.
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
Re-enter settings,
clean.
press and hold
For an optimum life-time, the battery packs have to be fully
Power button to
charged, after used.
power down the
tool before
To obtain the longest possible battery life remove the
removing the
battery pack from the charger once it is fully charged.
battery.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below
Remove the torque
27°C and away from moisture
and re-zero the
Store the battery packs in a 30% - 50% charged condition
tool.
Every six months of storage, charge the pack as normal.
Return to a service
BATTERY PACK PROTECTION
center to be
calibrated.
In extremely high torque, binding, stalling and short circuit
situations that cause high current draw, the tool will vibrate
Return to a service
for about 5 seconds, the fuel gauge will fl ash,and then the
center to be
tool will turn OFF. To reset, release the trigger.
calibrated.
Under extreme circumstances, the internal temperature of
Return to a service
the battery pack could raise too much. If this happens, the
fuel gauge will fl ash until the battery pack cooled down.
center.
After the lights go off , the work may continue.
Return to a service
center to be
TRANSPORTING LITHIUM BATTERIES
calibrated.
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Return to a service
Transportation of those batteries has to be done in
center to be
accordance with local, national and international provisions
calibrated.
and regulations.
• The user can transport the batteries by road without
further requirements.
Clear the data in
• Commercial transport of Lithium-Ion batteries by third
memory.
parties is subject to Dangerous Goods regulations.
Transport preparation and transport are exclusively to be
Return to a service
carried out by appropriately trained persons and the
center to be
process has to be accompanied by corresponding
calibrated.
experts.
Follow steps
When transporting batteries:
through warning to
• Ensure that battery contact terminals are protected and
proceed.
insulated to prevent short circuit.
• Ensure that battery pack is secured against movement
Turn the tool off
within packaging.
and remove the
• Do not transport batteries that are cracked or leak.
battery.
Check with forwarding company for further advice
Return to a service
center to be
calibrated.
Tool exceeded
Return to a service
the expiration
center to be
date that is
calibrated.
required for
certifi cation, tool
is overloaded, or
5000 tightening
cycles have
surpassed.