The dust produced when using this tool may be harmful to
health. Do not inhale the dust. Wear a suitable dust
protection mask.
Do not machine any materials that present a danger to
health (e.g. asbestos).
Switch the device off immediately if the insertion tool stalls!
Do not switch the device on again while the insertion tool is
stalled, as doing so could trigger a sudden recoil with a
high reactive force. Determine why the insertion tool stalled
and rectify this, paying heed to the safety instructions.
The possible causes may be:
• it is tilted in the workpiece to be machined
• it has pierced through the material to be machined
• the power tool is overloaded
Do not reach into the machine while it is running.
The insertion tool may become hot during use.
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the
machine is running.
When working in walls ceiling, or fl oor, take care to avoid
electric cables and gas or waterpipes.
Clamp your workpiece with a clamping device. Unclamped
workpieces can cause severe injury and damage.
Remove the battery pack before starting any work on the
machine.
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors off er to
retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only System M12 chargers for charging System M12
battery packs. Do not use battery packs from other
systems.
Never break open battery packs and chargers and store
only in dry rooms. Keep dry at all times.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least
10 minutes and immediately seek medical attention.
Warning! To reduce the risk of fi re, personal injury, and
product damage due to a short circuit, never immerse your
tool, battery pack or charger in fl uid or allow a fl uid to fl ow
inside them. Corrosive or conductive fl uids, such as
seawater, certain industrial chemicals, and bleach or
bleach containing products, etc., can cause a short circuit.
WARNING This device contains a lithium
button/coin cell battery. A new or used battery
can cause severe internal burns and lead to
death in as little as 2 hours if swallowed or
enters the body. Always secure the battery
cover. If it does not close securely, stop using the device,
remove the batteries, and keep it away from children. If you
think batteries may have been swallowed or entered the
body, seek immediate medical attention.
SPECIFIED CONDITIONS OF USE
The digital torque wrench can be used to tighten and
loosen non-live nuts and bolts.
Do not use this product in any other way as stated for
normal use.
470 221 - M12 ONEFTR38, M12 ONEFTR12.indd 17
470 221 - M12 ONEFTR38, M12 ONEFTR12.indd 17
DISPLAY AND BUTTONS
1
Mode - 50.0 NM, -5.0/+5.0%
NM
Range: -5.0/+5.0%
5
6
7
1 Menu
2 Battery indicator
3 Arrow buttons
4 Power button
5 Target torque indicator
6 Selected torque
7 Number of stored reports
8 OK button
9 Saved reports button
10 Exit button
Target torque indicator
The target torque indicator will display the progress to
achieving the target torque in percent.
2 LED white: 20% reached
4 LED white: 40% reached
6 LED white: 60% reached
All LED white: 80% reached
All LED green: 100% reached
All LED red: exceeded target
torque.
MENU GUIDE
Open menu
Navigate throughout the menu guide
Modify settings
Set a function within each category
Exit each page
Save reports
Description
Function
Calibration
This tool was calibrated at the factory
with torque measurement instruments.
Contact a MILWAUKEE service facility
for calibration. Torque parameters
comply with ISO 6789-2003 or ASME
B107-28- 2010.
Modes
Add preset functions to a profi le: setup
units, target torque, and a percentage
range.
Saved Events
Allow for grouping events and to view
recent history. (see "saved events/
grouping" section.)
Grouping
Organize events by saving to an open
group. (see "saved events/ grouping"
section.)
ENGLISH
2
3
4
8
9 10
17
08.11.2019 09:22:00
08.11.2019 09:22:00