Big Biz Trouble Shooting Guide - ELMECO BIG BIZ Manuel D'utilisation Et De Maintenance

Masquer les pouces Voir aussi pour BIG BIZ:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Big Biz trouble shooting guide

For all manual interventions, always make sure the machine is switched off and disconnected from the power
supply.
On the electronic board the
leds "1" and "slush" mode
blinks and the augers are
rotating.
On the electronic board the
leds "1" and "slush" mode
blinks and the augers are
stopped.
On the electronic board the led
2 blinks.
The tank does not make cold,
the cooling light is off
During the augers rotation you
can hear a creaking.
The machine does not make
cold and the "slush" led, "cold
drink" led and "1" led blink on
the electronic board.
To the ignition of the machine
in "slush" mode start to blink
the "3" led
Check the connection between the electronic board and the brushless gearmotor. Check for the
presence of oxide on the two connectors.
Probable damage of the electronic board or of the brushless gearmotor.
Replace the cable that connects the thermostat probe to the electronic board verifying that there
is not oxide on it; if so, clean the contacts and if the problem still exists, it is necessary to substitute
the thermostat probe.
Empty the tank;
switch off the slush machine by the main switch;
pour into the tank a product with a temperature higher than 15°C;
wait 5 minutes at least and switch on the machine again;
select on the electronic board "slush" mode;
The electronics calibration is automatic and the status will be displayed on the electronic
board by the blink of led "3". The blink will stop when the calibration will be finished.
This noise derives from the vertical and horizontal augers gears. You can avoid this by putting some
Vaseline on the plastic gears.
The machine is in protection mode. The increasing of the internal temperatures start this mode.
The machine is equipped with an automatic reset pressure switch; when the pressures have
decreased, the compressor will start working again and the LEDs will stop flashing.
To avoid repeating this situation, make sure the machine is positioned correctly as shown in fig. 5
in appendix-58, and carry out the condenser cleaning procedure described on page 21.
To the ignition of the machine the electronic board, if the product temperature is higher than 5°C,
start with calibration procedure. Totally it will last 2 minutes, and for all this period of time the "3"