Timer Defrost; Important Security Rules; Disposal Of The Old Machine; Technical Assistance - ELMECO BIG BIZ Manuel D'utilisation Et De Maintenance

Masquer les pouces Voir aussi pour BIG BIZ:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

If the product freeze completely turn off the machine, wait until the product becomes completely liquid, empty
the tank and check the cause of the problem (ie. Lack of sugar, failure to close solenoid valve, etc.).
The product must be maintained at a temperature not exceeding 5°C for periods specified by the manufacturer,
but for not more than 5 days. In case of failure of the refrigerator system the product should be inspected to
determine whether it has deteriorated.
The "Timer Defrost" function is optional. The machine is endowed with a clock timer that, if properly regulated, changes
the "slush" function in "cold drink" and vice versa. This function grants a cold product with a 4°C temperature (+/-1°C),
even during the night (Night Mode), with a great advantage especially for milk-based products.
The "Timer Defrost" function is not activated on the machine.
The setting and the activation of the Night Mode and Day Mode is done when the machine is installed in the following
way:
1. Open the back and right panels;
2. Set local time, Night Mode and Day Mode hour on the timer; see instructions provided with this instruction manual;
3. panels closing.
Do not touch the machine with wet hands or feet.
Do not use the machine bare footed.
The appliance is only to be installed in locations where its use and maintenance is restricted to trained personnel.
This appliance is not intended to be installed in kitchens.
Do not expose the machine to the weather.
Do not pull the power wire in order to disconnect the machine from the electrical network.
Do not remove the panels before disconnecting the machine from the electrical network.
Do not remove protections and / or covers that require the use of tools for their removal.
Discarded machine must be unusable. Unplug the machine and cut the power wire.
The refrigerators produced, like most other refrigeration, freezing and air conditioners on the market, use Freon as a
refrigerant gas. Freon, like other coolants, is a gas with a high environmental impact.
Even if the type of gas that the supplier uses for the production of its machinery is environmentally friendly (R290 -
Propano), the Company in question nonetheless requires purchasers to be aware of the following, from the time of
purchase, follow the reference standards. All refrigerating machines must be disposed by the local administration service
or by an equivalent private authorized company. Take care not to damage the rigid tubes of the refrigerator until they are
taken back in order to be carefully and ecologically disposed.
All packaging materials used can be disposed without any danger.
Only an authorized service center can repair the machines (e.g. a power cord substitution) using original spare partsThe
out-of-use machines must be disabled. Disconnect the plug from the electrical network and cut the cable.
Warning! Any assistance work on machines loaded with R290 refrigerant must be performed by
knowledgeable and experienced person on the R290 gas management procedures. The activities must be
carried out by personnel designated by the manufacturer or the distributor who made the sale of the product
Timer defrost (BB2 optional)

Important Security Rules

Disposal of the old machine

Ecological instructions

Technical assistance