Commissioning
The most important codes for commissioning
Code
No.
Name
C0148
Motor
*
parameter
s
identification
C0517
User menu
*
v
1 Memory 1
2 Memory 2
3 Memory 3
4 Memory 4
5 Memory 5
6 Memory 6
7 Memory 7
8 Memory 8
9 Memory 9
10 Memory 10
C0608
Fan
*
monitoring
122
Possible settings
Lenze
Selection
0
0
Ready
1
Start identification
l
V/f−rated frequency (C0015), slip
compensation (C0021) and
motor stator inductivity (C0092)
are calculated and saved.
l
The motor stator resistance
(C0084) = total resistance of
motor cable and motor is
measured and saved
50
C0050 Output frequency (MCTRL1−NOUT)
34
C0034 Analog setpoint selection range
7
C0007 Fixed configuration − digital input
signals
10
C0010 Minimum output frequency
11
C0011 Maximum output frequency
12
C0012 Acceleration time main setpoint
13
C0013 Deceleration time main setpoint
15
C0015 V/f rated frequency
16
C0016 U
boost
min
2
C0002 Parameter set transfer
0
0
Not active
1
TRIP error message
2
Warning
EDK82MV222 DE/EN/FR 8.0
IMPORTANT
Only when the motor is cold!
1. Inhibit controller, wait until
drive is in standstill
2. Enter the correct motor data
under C0087, C0088,
C0089, C0090, C0091 (see
motor nameplate).
3. C0148 = set 1 by v
4. Enable controller
The identification
– starts, c gets out
– the motor makes a
high−pitched tone, but
does not rotate!
– takes approx. 30 s
– is completed when c is
on again
5. Controller inhibit
After mains switching or
l
when using the function
g the code from C0517/1
will be displayed.
In Lenze setting, the user
l
menu contains the most
important codes for setting
up the control mode "V/f
characteristic control with
linear characteristic"
l
When the password
protection is activated, only
the codes entered under
C0517 are freely accessible.
Enter the required code
l
numbers in the subcodes.
Codes, which are only active
when being used together
with an Application−I/O,
cannot be entered!
8200 motec 3 ... 7.5 kW:
Function must be activated
during commissioning!
Otherwise, the controller may
be destroyed through
overheating.
For all other controllers:
It is essential to set C0608 = 0.
L