15.
Start the motor parameter
identification (C0148)
A Ensure that the controller is
inhibited
B Set C0148 = 1
C Enable the controller
D If the segment c becomes
active after approx. 30 s, inhibit
the controller once again.
L
}
20
Press TV in addition
X3
20
}
20
EDK82MV222 DE/EN/FR 8.0
Commissioning
Vector control
Only when the motor is
cold!
X3
Terminal X3/28 = LOW
28
misc001
Terminal X3/28 =
l
28
HIGH
misc002
The identification
l
starts:
– The segment c
is off
– The motor
consumes current
and makes a
tone.
– The motor does not
rotate!
X3
l
Terminal X3/28 =
LOW
28
misc001
Identification is
l
completed.
Calculated and
l
stored:
– V/f rated frequency
(C0015)
– Slip compensation
(C0021)
– Motor stator
inductance (C0092)
Measured and stored:
l
– Motor stator
resistance (C0084)
= Total resistance
of motor cable and
motor
7