7
Commissioning
Vector control
12.
Activate the control mode "vector
control" (C0014 = 4)
Lenze setting: Linear V/f
characteristic control (C0014 =
2)
13.
Adapt the voltage/current range
for the analog setpoint selection
(C0034)
Lenze setting: −0−,
(0 ... 5 V/0 ... 10 V/0 ... 20 mA)
14.
Enter the motor data
A Rated motor speed (C0087)
Lenze setting: 1390 rpm
B Rated motor current (C0088)
Lenze setting: Depending on the
controller
C Rated motor frequency (C0089)
Lenze setting: 50 Hz
D Rated motor voltage (C0090)
Lenze setting: Depending on the
controller
E Motor−cosj (C0091)
Lenze setting: Depending on the
controller
108
d
c
b
B
p
SHPRG
Menu
0014
Code
Para
V e c t o r - C t r l
z
d
c
w x
Œ
j g f k i h PS
m n o
y
p
q
r
Hi
Lo
EDK82MV222 DE/EN/FR 8.0
A
00
4
9371BC008
b
e
a
Set the DIP switch on the
1
0034
000
standard I/O to the same
0
range (see Mounting
Instructions for the
standard I/O)
See motor nameplate
Enter the value for the
motor connection type
(star/delta) selected!
Enter the value for the
motor connection type
(star/delta) selected!
L