7
Commissioning
The most important codes for commissioning
Code
No.
Name
C0007
v
uSEr
(cont.)
C0010
Minimum
output
uSEr
frequency
C0011
Maximum
output
uSEr
frequency
C0012
Acceleration
time main
uSEr
setpoint
118
Possible settings
Lenze
Selection
E4
41
JOG1/3
42
QSP
43
CW/CC
W
UP
44
45
CW/CC
W
46
M/Re
47
CW/QSP
PCTRL1
48
− OFF
49
PCTRL1
− OFF
PCTRL1
50
− OFF
DCB
51
255
Free configuration under C0410
0.00 0.00
à
14.5 Hz
50.00 7.50
à
87 Hz
5.00 0.00
EDK82MV222 DE/EN/FR 8.0
E3
E2
E1
DCB
TRIP set DFIN1−O
N
DCB
TRIP set DFIN1−O
N
QSP
TRIP set DFIN1−O
N
DOWN
PAR
DFIN1−O
N
QSP
PAR
DFIN1−O
N
PAR
QSP
JOG1/3
CCW/QS
M/Re
JOG1/3
P
PCTRL1
DCB
DFIN1−O
−I−OFF
N
JOG1/3
QSP
DFIN1−O
N
PCTRL1
JOG1/3
DFIN1−O
−I−OFF
N
PAR
PCTRL1
DFIN1−O
−I−OFF
N
{0.02
650.00
Hz}
{0.02
650.00
Hz}
{0.02
1300.00 Reference: frequency change 0
s}
IMPORTANT
Only display
Do not change C0007 since
settings under C0410 can be
lost
C0010 is not effective with
l
bipolar setpoint selection
(−10 V ... + 10 V)
C0010 only defines the
l
analog input 1
à
Speed setting range 1 : 6
for Lenze geared motors:
Setting absolutely required
for operation with Lenze
geared motors.
Hz ... C0011
ð
Additional setpoint
l
C0220
Acceleration times can be
l
activated via digital signals
ð
C0101
L