(logic)
TABLE "B" LOGIC MENU
DEFAULT
LOGIC
OFF
TCA
OFF
antipanic
OFF
ASTER
OFF
revolving
OFF
iNT EXT
TEST PHOT
OFF
open
TEST PHOT
OFF
close
ra blow c. o p
OFF
OFF
fixed code
OFF
radio prog
All the other activation and safety inputs are managed autonomously by the
INTERNAL and EXTERNAL door. To set cage mode, you must:
- set the cage dipswitch to ON on the INTERNAL and EXTERNAL door
- set the "int ext" dipswitch to ON on the EXTERNAL door
- set the "int ext" dipswitch to OFF on the INTERNAL door
Definition of individual radar modes
• Radar A external door (1)
With doors closed, it activates opening of the external door and allows entry
inside the cage door. If the internal door is open, this door is closed before
the external door is opened. In the event of simultaneous operations, the
external door is given priority. Once the external door is closed, it activates
opening of the internal door and allows entry inside the building.
• Radar B
positioned in the middle of the cage door
presence of a person inside the cage door and, during exit, allows the external
door to open once the internal door has closed. In an emergency, once the
person has entered the cage door, if the other door fails to open, it allows the
door they have just entered through to be opened again.
• Radar C internal door (2)
With doors closed, it activates opening of the internal door and allows entry
inside the cage door from inside the building. If the external door is open,
this door is closed before the internal door is opened. In the event of simul-
taneous operations, the external door is given priority.
24
- VISTA SL
INSTALLATION MANUAL
Cross out
using
setting
ON
Automatic Closing ON/OFF (TCA and Clear Time)
OFF
ON
Panic Feature ON/OFF (Section ANTI-PANIC FUNCTION)
OFF
Master/Slave door (Sect. CONNECTING A NUMBER OF DOORS WITH CENTRAL CONTROL PANELS)
ON
"ON" Door set as MASTER in connection for management of commands via central controllers.
OFF
"OFF" Door set as SLAVE in connection for management of commands via central controllers.
ON
"ON" Revolving mode. Single/revolving door (Sect. CONNECTING 2 DOORS IN cage MODE)
"OFF" Single door mode
OFF
Internal/External door (Sect. CONNECTING 2 DOORS IN cage MODE)
ON
"ON" Door set as EXTERNAL in "Revolving" mode.
OFF
"OFF" Door set as INTERNAL in "Revolving" mode.
Safety device testing during opening
ON
"ON" Device testing ON during opening
OFF
"OFF" Device testing OFF during opening
Safety device testing during closing
ON
"ON" Device testing ON during closing
OFF
"OFF" Device testing OFF during closing
ON
Hammer ON/OFF during opening
OFF
ON
ON:
Receiver is configured for operation in fixed-code mode.
OFF: Receiver is configured for operation in rolling-code mode.
OFF
ON:
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already been
ON
memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
OFF
OFF: Disables wireless memorizing of transmitters. Transmitters are memorized only using the relevant Radio
menu.
In normal mode, it detects the
DESCRIPTION