9. Check the exhalation valve: seal the mask connector and breathe
out forcefully.
The exhaled air must be able to escape without obstruction. If not,
replace the exhalation valve disc (see Chapter 4.3.6 on Page 20).
10. Connect either respiratory filter, powered air purifying respirator,
SCBA or airline equipment.
WARNING
!
The full face mask must only be used if perfectly tight;
otherwise there is a danger of poisoning!
3.4

During use

3.4.1
Low temperatures
Protect the inside of the visor against fogging with "klar-pilot" anti-fog
agent.
3.4.2
High temperatures
WARNING
!
If bubbles appear in the visor, it is a sign that the visor is
becoming soft. In this case leave the danger zone
immediately, since the full face mask can start to leak.
3.4.3
Chemicals
Some substances can be absorbed by the material of the mask body
or may even diffuse through it. Further information can be obtained
from Dräger .
Dräger X-plore 6000
3.5

After use

1. Disconnect the respiratory filter, lung demand valve or connecting
hose from the powered air purifying respirator or airline equipment.
2. Remove the full face mask:
Insert your index fingers underneath the flaps of the neck straps
and push the adjusting clamps forward with your thumbs to loosen
the head harness (see Figure F). Pull the full face mask away from
your face and over your head.
3. Dispose of the respiratory filter in accordance with the local waste
disposal regulations.
CAUTION
!
Do not grab full face mask by the connector and pull it off your
face, since the mask may become damaged.
(approved by Dekra Exam)