After use

Release the demand valve or breathing filter
Dispose of the breathing filter
Remove the full face mask:
Insert index finger behind the tabs on
the neck straps and press the buckles
forwards with the thumbs whilst
simultaneously pulling the full face
mask forward off your face and then up
and back over your head.
Maintenance
Always test for leaks after servicing and/or replacing components.

Cleaning and disinfection

Before cleaning, remove any accessories from the mask and clean
1)
them separately
.
The full face mask must be cleaned and disinfected after every use.
The mask body must be cleaned sufficiently thoroughly that no
residues from skin care products remain on it.
Otherwise there could be a loss of elasticity in the sealing area and
the mask will no longer sit correctly.
Failure to heed this warning could result in poisoning or death.
1)
Observe the corresponding operating manual.
12
1)
.
1)
.
WARNING
Do not use solvents such as acetone, alcohol or similar for cleaning.
Use only the cleaning agents and disinfectants listed below.
Excessive dosing and extended exposure times that deviate from
the specifications described here or from the specifications of the
manufacturer of the cleaning and disinfection agent, can cause
damage to the full face mask, e.g. the visor can become brittle.
Do not use a cloth to clean or dry the inside of full face masks with
visors that are marked "PC/CC", as the coating can be damaged as
a result. After drying, these full face masks should be aired
unpacked for at least one day under standard climatic conditions
according to DIN EN ISO 291, so that the coating can regenerate
and the optimum working life is achieved.
Clean and disinfect the full face mask as follows:
Clean the full face mask using water (max. 30 °C) with a universal
cleaning agent, Sekusept Cleaner
Immediately afterwards, remove the cleaning agent completely
under running water.
Immerse the full face mask for 15 minutes in the disinfectant bath
®1)
(max. 30 °C) with Incidur
Immediately afterwards, remove the disinfectant completely under
running water.
Leave the full face mask to dry thoroughly in a drying cabinet or in
the open air. Temperature max. 60 °C. Do not expose to direct
sunlight.
Testing
Test the full face mask in accordance with the test and maintenance
intervals.
CAUTION
®1)
(0.5-1.0 % solution).
disinfectant (2 % solution).