For Your Safety; Accessories - Dräger Panorama Nova RA Mode D'emploi

Masquer les pouces Voir aussi pour Panorama Nova RA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16

For your safety

Strictly follow the operating manual
Any use of the full face mask requires full understanding and strict
observation of this operating manual.
The full face mask may only be used for the purposes specified here.
Maintenance
The full face mask must be regularly inspected and maintained by
specialists.
Only have repairs carried out by specialists.
We recommend taking out a service contract with Dräger and having
all repairs carried out by Dräger.
Only original Dräger parts may be used for maintenance.
Note the instructions in the chapter entitled "Maintenance intervals".

Accessories

Only use the accessories listed in the ordering list.
Use in potentially explosive atmospheres
Full face masks that are used in potentially explosive atmospheres
and have been tested and approved to national, European or
international explosion protection standards, may only be used under
the conditions specified in the approval and with regard to the relevant
statutory regulations.
No modifications may be made to the equipment.
The use of defective or incomplete parts is not permissible.
The corresponding regulations must be observed when carrying out
repairs to these components or apparatus.
Description
What's what
6
5
4
3
2
1
12
11
1
Connector
2
Control valve
3
Inner mask
4
Visor
5
Visor frame
6
Front head strap
Description/Purpose
The full face mask protects the face and eyes from hostile media.
Wearers of spectacles can use mask spectacles. A welder´s
protective visor can be upgraded for this. Usable over a temperature
range of -30 °C to +60 °C.
7
8
9
10
7
Harness
8
Face seal
9
Carrying strap
10 Mask body
11 Clamping ring
12 Exhalation valve cover
9

Publicité

Table des Matières
loading

Table des Matières