The full face masks are tested in accordance with 2014/34/EU for use
in hazardous areas and can be used in the following zones:
Zone 0, 1, 2 for gases
of explosion group IIA, IIB, IIC
Zone 0, 1, 2 for gases
of explosion group IIA, IIB
Zone 1, 2 for gases of
explosion group IIA, IIB, IIC
Zone 1, 2 for gases of
explosion group IIA, IIB
Dust explosive atmospheres of zone
21, 22
Dräger X-plore 6000
X
X
X
X
X
X
(approved by Dekra Exam)
2.6
Type-identical marking
The full face masks are marked differently:
Connector
RA
EPDM or Si,
X-plore 6300 EN 136:1998 CL. 2 or
Mask body
X-plore 6500 EN 136:1998 CL. 3
CExxxx (notified body in Europe)
Visor
L, PC or PMMA
Visor frame
K/sw or K/bl