BFT RIGEL 5 Instructions D'utilisation Et D'installation page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
x 2
param. 1
param. 2
param. . . .
logic
logic. 1
logic. 2
logic. . . .
radio
add. start
Add. 2ch
erase 64
COD RX
v
PRG
default
ITA
OK
language
- +
FRA
OK
- +
DEU
OK
- +
ENG
OK
- +
esp
OK
stat
vers
OK
OK
- +
n. cycles
OK
- +
n. Remotes
OK
ACCESS TO MENUS Fig. 1
hidden button
hidden button
PRG.
+/-
2 2 F D
1 A 9 C
OK
DIAGNOSTICS
DESCRIPTION
CODE
EXTERNAL START input activation
stre
INTERNAL START input activation
stri
input activation PEDESTRIAN
ped
OPEN input activation
open
CLOSE input activation
cls
STOP input activation
stop
PHOT input activation
phot
activation of input for PHOTOCELL ON OPENING
phop
activation of input for PHOTOCELL ON CLOSING
phcl
input activation SAFETY EDGE
bar
activation of input for MOTOR 1 CLOSING LIMIT
svc1
SWITCH
activation of input for MOTOR 1 OPENING
svo1
LIMIT SWITCH
activation of input for MOTOR 2 CLOSING LIMIT
svc2
SWITCH
bft rigel 5
activation of input for MOTOR 2 OPENING
svo2
+/-
LIMIT SWITCH
TIMER input activation
ti e
0000
photocell test anomaly
Er01
+/-
safety edge test anomaly
Er02
00
photocell on opening test anomaly
er03
+/-
photocell on closing test anomaly
er04
Er1X *
hardware anomaly
solenoid lock output overload
erf9
* X = 0,1,...,9,A,B,C,D,E,F
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
0 1
OK
OK
DIAGNOSTICS and WARNINGS
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
ok 01
ok 01
NOTES
check photocell connection and/or
parameter/logic settings
check safety edge connection and/or
parameter/logic settings
check photocell connection and/or
parameter/logic settings
check photocell connection and/or
parameter/logic settings
check connections to motor
check solenoid lock connections
RIGEL 5 -