Maintenance Every 2 Years; Maintenance Every 6 Years; Cleaning And Care Of The System - ATT NUSSBAUM SPRINTER MOBIL 2500 Manuel D'exploitation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Torque (Nm) for shaft screws
Fastening class 8.8
0.11*
0.15**
M8
20
M10
40
M12
69
M16
170
M20
340
M24
590
Fastening class 10.9
0.11*
0.15**
M8
30
M10
59
M12
100
M16
250
M20
490
M24
840
*
Slide friction number 0.10 for very good surface,
lubricated
**
Slide friction number, 0.15 for good surfaces,
lubricated or dry
*** Slide friction number 0.20 surface black or
phosphated, dry
• The system is fi tted with no-maintenance DU
sliding bearings. Despite this, due to environmen-
tal infl uences of various kinds (e.g. humidity, dust,
dirt) bearing zones may become noisy.
In this case, spray the affected areas with an acid
and resin free oil spray (no adhesive oil or biologi-
cally degradable oil). Noises normally occur after
the system has been raised and lowered several
times.
• Check the function of the CE STOP with warning
signal.

6.1.3 Maintenance every 2 years

• Change the hydraulic oil according to manufac-
turers instructions.
62
0.20***
25
30
50
60
87
105
220
260
430
520
740
890
0.20***
37
44
73
87
125
151
315
380
615
740
1050
1250

6.1.4 Maintenance every 6 years

• Exchange the protective and hydraulic hoses.
Excerpt from BGR 237
Specifi cations for the hydraulic hose lines:
• Normal specifi cation:
6 years including 2 years storage time.
• Increased demands e.g. due to increased
usage times, e.g. multi-shift operation, short cy-
cle times and pressure impulses and large ex-
ternal and internal (due to medium) infl uences
which signifi cantly reduce the lifetime of the
hose lines:
2 year operation duration
6.2

Cleaning and care of the system

A regular and expert clean helps retain the value
of the system.
Additionally, it can also be a pre-requisiste for the
preservation of guarantee claims for any eventual
corrosion damage.
The best protection for the system is regular
removal of contaminants of any kind.
This includes above all:
• De-icing salt
• Sand, pebbles, earth
• Industrial dust of all types
• Water, also in connection with other environmen-
tal infl uences
• Aggressive deposits of all types
• Permanent humidity due to insuffi cient ventilation
The frequency of system cleaning depends, among
other things on the frequency of use, of system han-
dling, of workshop cleanliness, and the location of
the system.
Furthermore, the degree of contamination de-
pends on the time of year, the weather conditions
and workshop ventilation.
Under adverse circumstances, weekly system
cleaning might be required, however a monthly
cleaning may be suffi cient.
SPRINTER MOBIL - HYMAX PRO
12.06.2015
AD H9451

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sprinter mobil 3000Hymax pro 2500Hymax pro 3000

Table des Matières