Becker Centronic UnitControl UC520 Notice De Montage Et D'utilisation page 33

Masquer les pouces Voir aussi pour Centronic UnitControl UC520:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Intermediate position II
Application
Roller shutter operation
Awning operation
Venetian blind operation
Note
This function allows you to open the curtain from the lower limit position
until the desired intermediate position II is reached. Both limit positions
must be set before the intermediate position II is set.
a) Setting the intermediate position II
Requirement: The curtain must be in the lower limit position.
1. Press and hold the programming button Intermediate position II s.
2. Then press the UP button until the desired intermediate position II is reached.
Use the UP and DOWN buttons to make any corrections.
3. Release the programming button Intermediate position II s. The indicator
lamps flash briefly three times.
The intermediate position II is now saved.
b) Checking the intermediate position II
1. Press the UP button twice within one second.
The curtain runs to the intermediate position II.
c) Deleting the intermediate position II
Press the programming button Intermediate position II s for longer than 5 sec-
onds. The indicator lamps flash briefly three times.
The intermediate position II is now deleted.
Information for the operation of the venetian blind
For the blind function, the blind moves in touch mode in order to enable
an exact positioning of the laths. If you press a travel button for longer
than 1 second, the blind switches to maintained operation.
If an intermediate position II is saved, the blind will run to this position
after travelling to intermediate position I. If there is no intermediate
position I saved, the blind will run to intermediate position II after the
running time has elapsed.
Function
Ventilation
Cloth tension
Turning
de
en
fr
nl
33

Publicité

Table des Matières
loading

Table des Matières